Literature DB >> 6851333

A canine cementless total hip prosthesis model.

P Q Chen, T M Turner, H Ronnigen, J Galante, R Urban, W Rostoker.   

Abstract

To evaluate a porous fiber titanium composite as a fixation method, total hip arthroplasty was performed in 13 large male mongrel dogs. In seven both acetabular and femoral composites were fixed with a porous titanium fiber composite, and in the other six the acetabulum was fixed with acrylic cement. The animals were killed one, three, and six months following implantation. At autopsy all components were fixed by bony ingrowth. There was progressive remodeling of the ingrown bone and of the bone trabeculae surrounding the prosthesis in the three- and six-month animals, with gradual thickening and development of haversian structures. Cortical osteoporosis, which did not appear to be progressive, was detected in both the one- and six-month specimens.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6851333

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  6 in total

1.  Cementless fixation of hip prostheses in dogs.

Authors:  P Massin; O Badelon; R Cavagna; L Bocquet; J Duparc
Journal:  Int Orthop       Date:  1991       Impact factor: 3.075

2.  Hip implant evaluation in an arthritic animal model.

Authors:  T W Phillips; K R Gurr; D R Rao
Journal:  Arch Orthop Trauma Surg       Date:  1990       Impact factor: 3.067

3.  Modular hybrid total hip arthroplasty. Experimental study in dogs.

Authors:  Bruno W Minto; Cláudia Valéria S Brandão; Gilberto J C Pereira; Daniela Campagnol; Maria Jaqueline Mamprim; Carlos Roberto Padovani; José J T Ranzani
Journal:  Acta Vet Scand       Date:  2011-07-07       Impact factor: 1.695

4.  Microscopic analysis of autograft bone applied at the interface of porous-coated devices in human cancellous bone.

Authors:  A A Hofmann; R D Bloebaum; M H Rubman; K N Bachus; R L Plaster
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

5.  Freezing of rat tibiae at -20°c does not affect the mechanical properties of intramedullary bone/implant-interface: brief report.

Authors:  Michael Diefenbeck; Thomas Mückley; Sergiy Zankovych; Jörg Bossert; Klaus D Jandt; Christian Schrader; Jürgen Schmidt; Ulrich Finger; Mathilde Faucon
Journal:  Open Orthop J       Date:  2011-06-17

Review 6.  The Clinical History and Basic Science Origins of Transcutaneous Osseointegration for Amputees.

Authors:  Jason Shih Hoellwarth; Kevin Tetsworth; Muhammad Adeel Akhtar; Munjed Al Muderis
Journal:  Adv Orthop       Date:  2022-03-18
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.