Literature DB >> 6851038

Augmentation of regional coronary blood flow by intra-aortic balloon counterpulsation in patients with unstable angina.

R M Fuchs, K P Brin, J A Brinker, P A Guzman, R R Heuser, F C Yin.   

Abstract

Intra-aortic balloon counterpulsation is capable of reducing afterload in patients with unstable angina. Whether it is also capable of augmenting coronary blood flow to poststenotic myocardium is controversial. We studied seven patients receiving maximal drug therapy and requiring balloon pumping for unstable angina as balloon volume and assist ratio were altered. All patients had greater than 90% stenosis of the proximal left anterior descending coronary artery. With maximal augmentation (40 cc balloon volume, 1:1 assist ratio) great cardiac vein flow, representing the efflux from the left anterior descending coronary artery bed, rose from a baseline of 52 +/- 20 to 67 +/- 25 ml/min (mean +/- SD, p = .004) and mean aortic diastolic pressure increased from 77 +/- 13 to 99 +/- 33 mm Hg (p = .004). Increased great cardiac vein flow correlated with increased mean aortic diastolic pressure across changes in balloon volumes (off, 20 cc, 30 cc, and 40 cc) and changes in assist ratio (off, 1:4, 1:2, and 1:1) (p = .02). However, the intermediate balloon volumes produced great cardiac vein flows at an intermediate level between full assist and no assist (p less than .05), whereas the intermediate assist ratios did not augment flow. Thus balloon pumping increased flow to a bed fed by collateral vessels or critical stenoses; this increased flow correlated with increased aortic diastolic pressure, indicating probable loss of autoregulatory ability.

Entities:  

Mesh:

Year:  1983        PMID: 6851038     DOI: 10.1161/01.cir.68.1.117

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  10 in total

1.  Computational analysis of the effect of the type of LVAD flow on coronary perfusion and ventricular afterload.

Authors:  Ki Moo Lim; In Su Kim; Seong Wook Choi; Byung Goo Min; Yong Soon Won; Heon Young Kim; Eun Bo Shim
Journal:  J Physiol Sci       Date:  2009-04-23       Impact factor: 2.781

Review 2.  Radiology of cardiac devices and their complications.

Authors:  J Dipoce; A Bernheim; H Spindola-Franco
Journal:  Br J Radiol       Date:  2014-11-20       Impact factor: 3.039

3.  In vivo impact of intra-aortic balloon counterpulsation on reducing ischemia and improving myocardial blood flow: Proof from a PET rubidium-82 study.

Authors:  Newton B Wiggins; Brett W Sperry; Joseph M Bumgarner; Elizabeth A Hill; Wael A Jaber
Journal:  J Nucl Cardiol       Date:  2015-07-10       Impact factor: 5.952

4.  IABP plus ECMO-Is one and one more than two?

Authors:  Sebastian Nuding; Karl Werdan
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

5.  The evolution of morphologic and biomechanical changes in reversed and in-situ vein grafts.

Authors:  R P Cambria; J Megerman; D C Brewster; D F Warnock; J Hasson; W M Abbott
Journal:  Ann Surg       Date:  1987-02       Impact factor: 12.969

6.  Histological changes in venous grafts.

Authors:  M J Underwood; A Coumbe
Journal:  J Clin Pathol       Date:  1994-01       Impact factor: 3.411

7.  Clinical characteristics and current management of medically refractory unstable angina.

Authors:  J S Rankin; J R Newton; R M Califf; R H Jones; A S Wechsler; H N Oldham; W G Wolfe; J E Lowe
Journal:  Ann Surg       Date:  1984-10       Impact factor: 12.969

8.  Biochemical (functional) adaptation of "arterialized" vein grafts.

Authors:  V J Henderson; R G Cohen; R S Mitchell; J C Kosek; D C Miller
Journal:  Ann Surg       Date:  1986-04       Impact factor: 12.969

Review 9.  IABP: history-evolution-pathophysiology-indications: what we need to know.

Authors:  H Parissis; V Graham; S Lampridis; M Lau; G Hooks; P C Mhandu
Journal:  J Cardiothorac Surg       Date:  2016-08-04       Impact factor: 1.637

10.  Effects of mechanical circulatory support devices in patients with acute myocardial infarction undergoing stent implantation: a systematic review and meta-analysis of randomised controlled trials.

Authors:  Yunmin Shi; Yujie Wang; Xuejing Sun; Yan Tang; Mengqing Jiang; Yuanyuan Bai; Suzhen Liu; Weihong Jiang; Hong Yuan; Yao Lu; Jingjing Cai
Journal:  BMJ Open       Date:  2021-06-29       Impact factor: 2.692

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.