Literature DB >> 6850825

The minimum error in estimating coronary luminal cross-sectional area from cineangiographic diameter measurements.

J R Spears, T Sandor, D S Baim, S Paulin.   

Abstract

A formal analysis of the error associated with the use of radiographic diameter measurements in estimating the luminal area of an elliptically-shaped coronary cross-section was performed. When two views are available, the maximum potential error was found to decrease rapidly as the angle between the views increased to 90 degrees, but this error was small (less than 25%) for orthogonal views only for mild degrees of ellipticity (major/minor axis ratio less than 2). Since, for each successive doubling of the number of radiographic views, a stepwise reduction in the potential error by an approximate factor of only one-half was found, a large number of views is required to eliminate the potential error associated with diameter assessment of highly elliptical lumena.

Entities:  

Mesh:

Year:  1983        PMID: 6850825     DOI: 10.1002/ccd.1810090203

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  6 in total

1.  Features of the angiographic evaluation of the INTACT study. International Nifedipine Trial on Antiatherosclerotic Therapy.

Authors:  S Jost; J Deckers; W Rafflenbeul; H Hecker; U Nellessen; B Wiese; P G Hugenholtz; P R Lichtlen
Journal:  Cardiovasc Drugs Ther       Date:  1990-08       Impact factor: 3.727

2.  What to do with OCA results from multiple angiographic views?

Authors:  J H Reiber
Journal:  Int J Card Imaging       Date:  1995-09

Review 3.  Coronary angioscopy.

Authors:  C J White; S R Ramee; T J Collins; J P Murgo
Journal:  Tex Heart Inst J       Date:  1995

4.  Quantitative angioscopy: a novel method of measurement of luminal dimensions during angioscopy with the use of a "lightwire".

Authors:  J R Spears; M Ali; S J Raza; G S Iyer; S Ravi; R J Crilly; B Fromm; W F Cheong
Journal:  Cardiovasc Intervent Radiol       Date:  1994 Jul-Aug       Impact factor: 2.740

5.  Digital subtraction angiographic assessment of the coronary arteries and coronary flow reserve.

Authors:  R A Vogel; G B Mancini; E R Bates
Journal:  Int J Card Imaging       Date:  1985

6.  Clinical application of quantitative coronary angiography using the CAAS system: preliminary results of the INTACT study (International Nifedipine Trial on Antiatherosclerotic Therapy).

Authors:  S Jost; J W Deckers; U Nellessen; W Rafflenbeul; H Hecker; J H Reiber; P G Hugenholtz; P R Lichtlen
Journal:  Int J Card Imaging       Date:  1988
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.