| Literature DB >> 6849753 |
C Guignard, V Van Toi, C W Burckhardt, J L Schelling.
Abstract
1 The sensitivity to flickering light at various light frequencies (DeLange curve) was determined in 20 controls and 45 patients receiving maintenance doses of digoxin. 2 Flicker thresholds (mean percentage of maximal light modulation +/- s.d.; F 30 Hz) were 7.6 +/- 1.7 in controls and 9.4 +/- 1.7 in patients with optimal plasma digoxin levels (0.5-1.9 ng/ml), but they rose to 15.5 +/- 1.9 at subtoxic levels (2.0-3.0 ng/ml), and to 21.8 +/- 2.6 at toxic levels (above 3.0 ng/ml). 3 Flicker sensitivity was inversely correlated with plasma digoxin levels and returned to baseline values when the administration of digoxin was interrupted. 4 The DeLange curve seems to be a valuable tool to measure the toxic effects of digitalis on the visual system.Entities:
Mesh:
Substances:
Year: 1983 PMID: 6849753 PMCID: PMC1427866 DOI: 10.1111/j.1365-2125.1983.tb01485.x
Source DB: PubMed Journal: Br J Clin Pharmacol ISSN: 0306-5251 Impact factor: 4.335