Literature DB >> 6848408

Neuromuscular differentiation of the human pylorus.

K Schulze-Delrieu, S S Shirazi.   

Abstract

The mechanical activity of muscle strips from the gastroduodenal junction as obtained at operations was studied. Strips were cut so as to present the activity of the circular muscle layer of the antrum, the duodenum, the intermediate, or the distal pyloric sphincter. All strips increased and maintained a tension with increasing length, but distal sphincter strips did more so than the other types of strips. Phasic contractions were rare in distal sphincter strips, while all intermediate sphincter strips contracted at rates similar to antral strips. Electric field stimulation produced pure contractions in all responsive strips of the antrum and the intermediate sphincter. In most strips from the duodenum and distal sphincter the contraction response occurred during the stimulus, and the relaxation response far outlasted the stimulus. Distal sphincter strips had the larger relaxation responses, and duodenal strips had the larger contraction responses. Relaxation in response to electric stimulation, Ca++ withdrawal, or isoproterenol did not completely abolish the baseline tension of the distal sphincter. At least in its distal segment, muscle from the human pylorus differs from muscle of the antrum and the duodenum by its high baseline tension, its prominent neurogenic relaxation response, and its poor spontaneous contractile activity.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6848408

Source DB:  PubMed          Journal:  Gastroenterology        ISSN: 0016-5085            Impact factor:   22.682


  4 in total

1.  Extrinsic and intrinsic neural control of pyloric sphincter pressure in the dog.

Authors:  H D Allescher; E E Daniel; J Dent; J E Fox; F Kostolanska
Journal:  J Physiol       Date:  1988-07       Impact factor: 5.182

2.  Direct effects of motilin on isolated smooth muscle from various regions of the human stomach.

Authors:  F E Lüdtke; H Müller; K Golenhofen
Journal:  Pflugers Arch       Date:  1989-09       Impact factor: 3.657

3.  Pyloric motility. Sleeve sensor versus strain gauge transducer.

Authors:  M Edelbroek; J Schuurkes; W de Ridder; M Horowitz; J Dent; L Akkermans
Journal:  Dig Dis Sci       Date:  1994-03       Impact factor: 3.199

4.  Pyloric deformation from peptic disease. Radiographic evidence for incompetence rather than obstruction.

Authors:  C C Lu; K Schulze-Delrieu
Journal:  Dig Dis Sci       Date:  1990-12       Impact factor: 3.199

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.