Literature DB >> 6846494

A comparative study of tear evaporation rates and water content of soft contact lenses.

T H Cedarstaff, A Tomlinson.   

Abstract

Tear evaporation rates were measured by resistance hygrometry in a group of five subjects wearing soft contact lenses ranging in initial water content from 38 to 70%. The water content of the lenses before and after wear was measured by a "wet blot weighing" technique using a chemical balance. The placing of all types of soft lenses on the eye disrupts the tear film sufficiently to produce significant increases in evaporation. This increase in tear evaporation was not found to be related to the initial water content of the soft lens. Water lost by dehydration of the lens material made a relatively minor contribution to the increase in evaporation from the eye during lens wear.

Entities:  

Mesh:

Year:  1983        PMID: 6846494     DOI: 10.1097/00006324-198303000-00004

Source DB:  PubMed          Journal:  Am J Optom Physiol Opt        ISSN: 0093-7002


  9 in total

Review 1.  Eye complaints in the office environment: precorneal tear film integrity influenced by eye blinking efficiency.

Authors:  P Wolkoff; J K Nøjgaard; P Troiano; B Piccoli
Journal:  Occup Environ Med       Date:  2005-01       Impact factor: 4.402

Review 2.  The international workshop on meibomian gland dysfunction: report of the diagnosis subcommittee.

Authors:  Alan Tomlinson; Anthony J Bron; Donald R Korb; Shiro Amano; Jerry R Paugh; E Ian Pearce; Richard Yee; Norihiko Yokoi; Reiko Arita; Murat Dogru
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-03-30       Impact factor: 4.799

Review 3.  TFOS DEWS II Tear Film Report.

Authors:  Mark D P Willcox; Pablo Argüeso; Georgi A Georgiev; Juha M Holopainen; Gordon W Laurie; Tom J Millar; Eric B Papas; Jannick P Rolland; Tannin A Schmidt; Ulrike Stahl; Tatiana Suarez; Lakshman N Subbaraman; Omür Ö Uçakhan; Lyndon Jones
Journal:  Ocul Surf       Date:  2017-07-20       Impact factor: 5.033

Review 4.  Disease and risks associated with contact lenses.

Authors:  J K Dart
Journal:  Br J Ophthalmol       Date:  1993-01       Impact factor: 4.638

Review 5.  Tear analysis in contact lens wearers.

Authors:  R L Farris
Journal:  Trans Am Ophthalmol Soc       Date:  1985

6.  [Eyelid hygiene for contact lens wearers with blepharitis. Comparative investigation of treatment with baby shampoo versus phospholipid solution].

Authors:  R Khaireddin; A Hueber
Journal:  Ophthalmologe       Date:  2013-02       Impact factor: 1.059

7.  A Potential Alternative Orodispersible Formulation to Prednisolone Sodium Phosphate Orally Disintegrating Tablets.

Authors:  Essam A Tawfik; Mariagiovanna Scarpa; Hend E Abdelhakim; Haitham A Bukhary; Duncan Q M Craig; Susan A Barker; Mine Orlu
Journal:  Pharmaceutics       Date:  2021-01-19       Impact factor: 6.321

8.  Assessment of Dry Eye Syndrome Among Contact Lens Users in Asir Region, Saudi Arabia.

Authors:  Abdulrahman Alamri; Khaled A Amer; Abdulrahman A Aldosari; Sereen D Al-Muhsin; Razan S Al-Maalwi; Shahd A Al Hamdan; Lujane M Al-Tarish
Journal:  Cureus       Date:  2022-01-23

9.  A two-week clinical evaluation of the safety of Systane Ultra in contact lens-wearing patients.

Authors:  David Kading
Journal:  Clin Ophthalmol       Date:  2010-02-02
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.