Literature DB >> 6841393

Treatment of intertrochanteric fractures of the femur. A comparison of the Richards screw-plate with the Jewett nail-plate.

G H Heyse-Moore, A G MacEachern, D C Evans.   

Abstract

One hundred and seven patients with intertrochanteric fractures of the femur treated with a Richards screw-plate were compared retrospectively with 103 patients treated with a Jewett nail-plate. The mortality and morbidity were similar in the two groups. In patients with comparable fractures, those treated with a Richards device mobilised more quickly and left hospital sooner, and more of them returned to their homes. Failures of stabilisation, both clinically and radiographically, were fewer in this group. The reliability of fixation with a correctly positioned Richards screw-plate could justify the omission of outpatient follow-up in all but a small group of patients with severe unstable fractures or grossly defective bone stock. The higher cost of a Richards implant and the slightly longer operative procedure were outweighed by savings in occupancy of acute and long-stay hospital beds.

Entities:  

Mesh:

Year:  1983        PMID: 6841393

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  10 in total

1.  [Osteosynthesis of lesions of the proximal femur using dynamic screw plates. Multicenter study: 1871 cases].

Authors:  P Putz; E Coussaert; D Delvaux; P Long Pretz; R Thys; F Cantraine
Journal:  Int Orthop       Date:  1990       Impact factor: 3.075

Review 2.  The pathogenesis and treatment of hip fractures.

Authors:  P Lips; K J Obrant
Journal:  Osteoporos Int       Date:  1991-09       Impact factor: 4.507

3.  Trochanteric fractures--a clinical and radiologic evaluation of McLaughlin, Ender, and Richard's osteosynthesis.

Authors:  K Herrlin; T Strömberg; H Pettersson; A Wallöe; L Lidgren
Journal:  Arch Orthop Trauma Surg       Date:  1989       Impact factor: 3.067

Review 4.  Extramedullary fixation implants and external fixators for extracapsular hip fractures in adults.

Authors:  Martyn J Parker; Avishek Das
Journal:  Cochrane Database Syst Rev       Date:  2013-02-28

5.  The treatment of stable and unstable proximal femoral fractures with a new trochanteric nail: results of a multicentre study with the Veronail.

Authors:  Franco Lavini; L Renzi-Brivio; R Aulisa; F Cherubino; P L Di Seglio; N Galante; W Leonardi; M Manca
Journal:  Strategies Trauma Limb Reconstr       Date:  2008-03-29

6.  The value of a special surgical team in preventing complications in the treatment of hip fractures.

Authors:  M J Parker; G A Pryor; J W Myles
Journal:  Int Orthop       Date:  1994-06       Impact factor: 3.075

7.  Is a sliding hip screw or im nail the preferred implant for intertrochanteric fracture fixation?

Authors:  Brian Aros; Anna N A Tosteson; Daniel J Gottlieb; Kenneth J Koval
Journal:  Clin Orthop Relat Res       Date:  2008-05-09       Impact factor: 4.176

8.  Sliding-screw plate fixation of proximal femoral fractures: radiographic assessment.

Authors:  D J Sartoris; R Kerr; T Goergen; D Resnick
Journal:  Skeletal Radiol       Date:  1985       Impact factor: 2.199

9.  The effectiveness of primary bipolar arthroplasty in treatment of unstable intertrochanteric fractures in elderly patients.

Authors:  Khaldoun Sinno; Mazen Sakr; Julien Girard; Hassan Khatib
Journal:  N Am J Med Sci       Date:  2010-12

10.  Sliding hip screws and medial displacement osteotomy.

Authors:  D Nunn
Journal:  J R Soc Med       Date:  1988-03       Impact factor: 18.000

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.