Literature DB >> 6838955

Osseointegrated titanium fixtures in the treatment of edentulousness.

P I Brånemark, R Adell, T Albrektsson, U Lekholm, S Lundkvist, B Rockler.   

Abstract

A 91 per cent positive 5-9 year result has been reported when using titanium implants and gold bridges to restore edentulous jaws. About 400 consecutive patients have been operated. The reasons for the good results are believed to depend on the anchorage of the implants in the living bone without interposing soft tissue layers. Repeated X-rays ensuring a strict parallelism are used to indicate direct bone integration. Some implants had to be removed in spite of still being anchored in the bone. In these cases SEM and TEM provided direct evidence of an osseointegration.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6838955     DOI: 10.1016/0142-9612(83)90065-0

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  44 in total

1.  Gradient surface porosity in titanium dental implants: relation between processing parameters and microstructure.

Authors:  M G Kutty; S Bhaduri; S B Bhaduri
Journal:  J Mater Sci Mater Med       Date:  2004-02       Impact factor: 3.896

2.  Tetracycline-incorporated polymer nanofibers as a potential dental implant surface modifier.

Authors:  Marco C Bottino; Eliseu A Münchow; Maria T P Albuquerque; Krzysztof Kamocki; Rana Shahi; Richard L Gregory; Tien-Min G Chu; Divya Pankajakshan
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-07-13       Impact factor: 3.368

3.  Regulation of osteoclasts by osteoblast lineage cells depends on titanium implant surface properties.

Authors:  Ethan M Lotz; Michael B Berger; Zvi Schwartz; Barbara D Boyan
Journal:  Acta Biomater       Date:  2017-12-30       Impact factor: 8.947

4.  Allogeneic bone block for challenging augmentation-a clinical, histological, and histomorphometrical investigation of tissue reaction and new bone formation.

Authors:  Jonas Lorenz; Alica Kubesch; Sarah Al-Maawi; Frank Schwarz; Robert A Sader; Markus Schlee; Shahram Ghanaati
Journal:  Clin Oral Investig       Date:  2018-03-09       Impact factor: 3.573

5.  Error Estimation of Nanoindentation Mechanical Properties Near a Dissimilar Interface via Finite Element Analysis and Analytical Solution Methods.

Authors:  Y Zhao; T C Ovaert
Journal:  J Mater Res       Date:  2010-12       Impact factor: 3.089

Review 6.  Surface modification of zirconia dental implants by laser texturing.

Authors:  Welson Cunha; Oscar Carvalho; Bruno Henriques; Filipe S Silva; Mutlu Özcan; Júlio C M Souza
Journal:  Lasers Med Sci       Date:  2022-01-13       Impact factor: 3.161

7.  Bone tissue response to experimental zirconia implants.

Authors:  Ilja Mihatovic; Vladimir Golubovic; Jürgen Becker; Frank Schwarz
Journal:  Clin Oral Investig       Date:  2016-08-09       Impact factor: 3.573

8.  Differences between buccal and lingual bone quality and quantity of peri-implant regions.

Authors:  Do-Gyoon Kim; Kathy L Elias; Yong-Hoon Jeong; Hyun-Jung Kwon; Matthew Clements; William A Brantley; Damian J Lee; Jung-Suk Han
Journal:  J Mech Behav Biomed Mater       Date:  2016-01-02

Review 9.  [Transcutaneous osseointegrated prosthetic systems after major amputation of the lower extremity : A retrospective 3-year analysis].

Authors:  Marcus Örgel; Alexander Ranker; Afif Harb; Christian Krettek; Horst-Heinrich Aschoff
Journal:  Orthopade       Date:  2021-01       Impact factor: 1.087

10.  Nanotechnology and dental implants.

Authors:  Sandrine Lavenus; Guy Louarn; Pierre Layrolle
Journal:  Int J Biomater       Date:  2010-12-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.