Literature DB >> 6833479

Comparison of a new rapid plasma reagin card test with the standard rapid plasma reagin 18-mm circle card test and the venereal disease research laboratory slide test for serodiagnosis of syphilis.

E A Hambie, S A Larsen, M W Perryman, D E Pettit, R L Mullally, W Whittington.   

Abstract

The rapid plasma reagin (RPR) card test manufactured by Beckman Instruments, Inc., was compared, qualitatively and quantitatively, with the Venereal Disease Research Laboratory (VDRL) slide test and the standard RPR 18-mm circle card tests for the serodiagnosis of syphilis. Sera from 638 individuals were used in this study. Two pilot lots and two production lots of antigen were submitted by Beckman Instruments, Inc., for evaluation. Qualitative agreement among the three RPR card tests was 98.1%; between the Beckman RPR card and the VDRL slide tests, 95.0%; and between the reference RPR card and the VDRL slide tests, 95.5%. The Beckman RPR card test was 95.3% specific, whereas the specificities of the reference RPR card and the VDRL slide tests were 98.8% and 96.1%, respectively. Sensitivities of the three nontreponemal tests were: Beckman RPR card test production lots, 94.7%; reference RPR card test, 96.8%; and VDRL slide test, 90.6%. Quantitative agreement +/- 1 dilution among the three RPR card tests was 93.0%, whereas quantitative agreement was approximately 40% when both RPR card tests were compared with the VDRL slide test. We found the Beckman RPR card test comparable to the standard RPR card tests. Therefore, the decision of which test to use for the serodiagnosis of syphilis is at the discretion of the user.

Mesh:

Substances:

Year:  1983        PMID: 6833479      PMCID: PMC272616          DOI: 10.1128/jcm.17.2.249-254.1983

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  3 in total

1.  MODIFICATIONS OF THE RAPID PLASMA REAGIN (RPR) CARD TEST FOR SYPHILIS, FOR USE IN LARGE SCALE TESTING.

Authors:  J PORTNOY
Journal:  Am J Clin Pathol       Date:  1963-11       Impact factor: 2.493

2.  Evaluation of a new rapid plasma reagin card test as a screening test for syphilis.

Authors:  M W Perryman; S A Larsen; E A Hambie; D E Pettit; R L Mullally; W Whittington
Journal:  J Clin Microbiol       Date:  1982-08       Impact factor: 5.948

3.  The reagin screen test: a new reagin card test for syphilis.

Authors:  R W March; G E Stiles
Journal:  Sex Transm Dis       Date:  1980 Apr-Jun       Impact factor: 2.830

  3 in total
  1 in total

Review 1.  Syphilis in pregnancy.

Authors:  M Genç; W J Ledger
Journal:  Sex Transm Infect       Date:  2000-04       Impact factor: 3.519

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.