Literature DB >> 6833477

Reproducible enzyme-linked immunosorbent assay with a magnetic processing system for diagnosis of toxoplasmosis.

E Konishi, J Takahashi.   

Abstract

An enzyme-linked immunosorbent assay with polycarbonate-coated iron beads as the solid phase and with magnetic processing devices was evaluated for the quantitation of antibodies to Toxoplasma gondii in human serum samples. Under the parameters and other basic conditions determined in this study, the assay was highly reproducible: coefficients of variation for the absorbance values obtained with the positive serum were 2.42% in same-day tests and 3.75% in day-to-day tests. Significant correlations were observed between the present assay system and other conventional serological tests: correlation coefficients were 0.960 with the dye test and 0.929 with the latex agglutination test. Statistical analysis based on the frequency distribution of absorbance values for dye-test-positive and dye-test-negative serum samples gave feasible border lines for distinguishing between positive and doubtful samples (0.357) and between doubtful and negative samples (0.266). Under this diagnostic criterion, the results of our assay system agreed remarkably well with those obtained by the dye test and the latex agglutination test, with consistencies of 94.9 and 93.9%, respectively.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6833477      PMCID: PMC272612          DOI: 10.1128/jcm.17.2.225-231.1983

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  20 in total

1.  A microplate enzyme-immunoassay for toxoplasma antibody.

Authors:  A Voller; D E Bidwell; A Bartlett; D G Fleck; M Perkins; B Oladehin
Journal:  J Clin Pathol       Date:  1976-02       Impact factor: 3.411

2.  Immunoglobulin G and immunoglobulin M enzyme-linked immunosorbent assays and defined toxoplasmosis serological patterns.

Authors:  M E Camargo; A W Ferreira; J R Mineo; C K Takiguti; O S Nakahara
Journal:  Infect Immun       Date:  1978-07       Impact factor: 3.441

3.  Standardization of enzyme-linked immunosorbent assay (ELISA) and the detection of Toxoplasma antibody.

Authors:  J R Denmark; B S Chessum
Journal:  Med Lab Sci       Date:  1978-07

4.  Thermal characteristics of microtitre plates used in immunological assays.

Authors:  S M Burt; T J Carter; L J Kricka
Journal:  J Immunol Methods       Date:  1979       Impact factor: 2.303

5.  Semiautomation of Immunoassays by use of magnetic transfer devices.

Authors:  K O Smith; W D Gehle
Journal:  Methods Enzymol       Date:  1980       Impact factor: 1.600

6.  Variability in the adsorption properties of microtitre plates used as solid supports in enzyme immunoassay.

Authors:  L J Kricka; T J Carter; S M Burt; J H Kennedy; R L Holder; M I Halliday; M E Telford; G B Wisdom
Journal:  Clin Chem       Date:  1980-05       Impact factor: 8.327

7.  Enzyme-linked immunosorbent assay for detection of antibodies to Japanese encephalitis virus in swine sera.

Authors:  E Konishi; M Yamaoka
Journal:  Kobe J Med Sci       Date:  1982-02

8.  Standardized quantitative enzyme-linked immunoassay for antibodies to Toxoplasma gondii.

Authors:  T M Lin; S P Halbert; G R O'Connor
Journal:  J Clin Microbiol       Date:  1980-06       Impact factor: 5.948

9.  An enzyme-linked immunosorbent assay for detection of IgM antibodies to Toxoplasma gondii: use for diagnosis of acute acquired toxoplasmosis.

Authors:  Y Naot; J S Remington
Journal:  J Infect Dis       Date:  1980-11       Impact factor: 5.226

10.  Reverse enzyme immunoassay for detection of specific anti-Toxoplasma immunoglobulin M antibodies.

Authors:  E L Franco; K W Walls; A J Sulzer
Journal:  J Clin Microbiol       Date:  1981-05       Impact factor: 5.948

View more
  4 in total

1.  Comparison of the Vitek Immunodiagnostic Assay System with an indirect immunoassay (Toxostat Test Kit) for detection of immunoglobulin G antibodies to Toxoplasma gondii in clinical specimens.

Authors:  R L Sandin; C C Knapp; G S Hall; J A Washington; I Rutherford
Journal:  J Clin Microbiol       Date:  1991-12       Impact factor: 5.948

2.  Evaluation of MUREX SUDS Toxo test.

Authors:  N P Moyer; J D Hudson; W J Hausler
Journal:  J Clin Microbiol       Date:  1987-11       Impact factor: 5.948

3.  An enzyme immunoassay for immunoglobulin M antibodies to Toxoplasma gondii which is not affected by rheumatoid factor or immunoglobulin G antibodies.

Authors:  T M Lin; M W Chin-See; S P Halbert; J M Joseph
Journal:  J Clin Microbiol       Date:  1986-01       Impact factor: 5.948

4.  Characterization of pseudorabies virus antibody responses in young swine after infection and vaccination by using an immunoglobulin M antibody capture enzyme-linked immunosorbent assay.

Authors:  M B McCaw; T W Molitor; H S Joo
Journal:  J Clin Microbiol       Date:  1992-02       Impact factor: 5.948

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.