Literature DB >> 6833308

Failure properties of passive human aortic tissue. II--Biaxial tension tests.

D Mohan, J W Melvin.   

Abstract

Descending mid-thoracic aortas were obtained from 16 autopsies and biaxial inflation tests performed on the tissue at dynamic (approximately 20 s-1) and quasi-static (approximately 0.01 s-1) strain rates. A bubble inflation technique was developed for this purpose. Extension histories of the specimens were recorded photographically and values of ultimate stresses and extension ratios in biaxial stretch have been calculated. Under conditions of uniform biaxial stretch the tissue consistently failed in a direction perpendicular to the long axis of the aorta and pressure values at failure were greater by a factor of two in the dynamic tests than those in the quasi-static tests.

Entities:  

Mesh:

Year:  1983        PMID: 6833308     DOI: 10.1016/0021-9290(83)90044-1

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  19 in total

Review 1.  Matrix metalloproteinases and descending aortic aneurysms: parity, disparity, and switch.

Authors:  Tom P Theruvath; Jeffrey A Jones; John S Ikonomidis
Journal:  J Card Surg       Date:  2011-09-29       Impact factor: 1.620

2.  Investigation of inhomogeneous and anisotropic material behavior of porcine thoracic aorta using nano-indentation tests.

Authors:  Golriz Kermani; Ali Hemmasizadeh; Soroush Assari; Michael Autieri; Kurosh Darvish
Journal:  J Mech Behav Biomed Mater       Date:  2016-12-24

3.  Quasi-linear viscoelastic modeling of arterial wall for surgical simulation.

Authors:  Tao Yang; Chee Kong Chui; Rui Qi Yu; Jing Qin; Stephen K Y Chang
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-04-13       Impact factor: 2.924

4.  The degree of nonlinearity and anisotropy of blood vessel elasticity.

Authors:  J Zhou; Y C Fung
Journal:  Proc Natl Acad Sci U S A       Date:  1997-12-23       Impact factor: 11.205

Review 5.  The time has come to extend the expiration limit of cryopreserved allograft heart valves.

Authors:  Jan Burkert; Petra Kochová; Zbyněk Tonar; Robert Cimrman; Tereza Blassová; Ramadan Jashari; Radovan Fiala; Jaroslav Špatenka
Journal:  Cell Tissue Bank       Date:  2020-06-24       Impact factor: 1.522

6.  Isotropic Failure Criteria Are Not Appropriate for Anisotropic Fibrous Biological Tissues.

Authors:  Christopher E Korenczuk; Lauren E Votava; Rohit Y Dhume; Shannen B Kizilski; George E Brown; Rahul Narain; Victor H Barocas
Journal:  J Biomech Eng       Date:  2017-07-01       Impact factor: 2.097

Review 7.  Cause and control of automotive trauma.

Authors:  D C Viano
Journal:  Bull N Y Acad Med       Date:  1988-06

8.  Computational modeling of the strength of the ascending thoracic aortic media tissue under physiologic biaxial loading conditions.

Authors:  Spandan Maiti; James R Thunes; Ronald N Fortunato; Thomas G Gleason; David A Vorp
Journal:  J Biomech       Date:  2020-06-14       Impact factor: 2.712

9.  A Uniaxial Testing Approach for Consistent Failure in Vascular Tissues.

Authors: 
Journal:  J Biomech Eng       Date:  2018-06-01       Impact factor: 2.097

10.  Characterization of human female breast and abdominal skin elasticity using a bulge test.

Authors:  Mazen Diab; Nishamathi Kumaraswamy; Gregory P Reece; Summer E Hanson; Michelle C Fingeret; Mia K Markey; Krishnaswamy Ravi-Chandar
Journal:  J Mech Behav Biomed Mater       Date:  2019-12-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.