Correlation between velocity measurements from Doppler echocardiography and from M-mode contrast echocardiography.

R S Meltzer, B Diebold, N K Valk, D Blanchard, J L Guermonprez, C T Lancée, P Peronneau, J Roelandt.   

Abstract

The slope of an individual contrast trajectory on M-mode contrast echocardiography represents a physiological variable similar to that measured by Doppler echocardiography: the projection of the intracardiac velocity vector in the direction of the sound beam. To test the hypothesis that M-mode contrast echocardiography slope measurement can yield information quantitatively similar to Doppler measurements, we performed both simultaneously in 11 normal volunteers. A pulsed Doppler unit capable of simultaneous M-mode and Doppler display was used. Contrast was obtained by intravenous injection of 5% dextrose. Two independent observers measured velocity simultaneously by both techniques at eight to 16 points per subject. One observer repeated the measurements a month later. All subjects had contrast, and 10 had sufficient quality tracings for simultaneous Doppler and contrast slope measurements. The correlation between velocity measurements by both techniques was good, though velocities by Doppler echocardiography were less than by M-mode contrast echocardiography. We conclude that the component of flow velocity towards or away from the transducer can be measured from M-mode contrast trajectory slopes as well as by Doppler echocardiography. M-mode contrast echocardiography may provide a practical method for verifying or calibrating Doppler measurements in vivo.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6830660      PMCID: PMC481295          DOI: 10.1136/hrt.49.3.244

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  8 in total

1.  Diagnosis of tricuspid regurgitation by contrast echocardiography.

Authors:  R S Meltzer; D van Hoogenhuyze; P W Serruys; M M Haalebos; P G Hugenholtz; J Roelandt
Journal:  Circulation       Date:  1981-05       Impact factor: 29.690

2.  Pulsed Doppler echocardiographic detection of right-sided valve regurgitation. Experimental results and clinical significance.

Authors:  A D Waggoner; M A Quinones; J B Young; T A Brandon; A A Shah; M S Verani; R R Miller
Journal:  Am J Cardiol       Date:  1981-02       Impact factor: 2.778

3.  [Pulsed echo-Doppler diagnosis and evaluation of tricuspid valve, and interventricular and interatrial communication insufficiencies. Flowmeter study of shunts].

Authors:  C Veyrat; G Abitbol; M Berkman; M C Malergue; D Kalmanson
Journal:  Arch Mal Coeur Vaiss       Date:  1980-09

4.  [Pulmonary flow velocity patterns in patients with pulmonary hypertension: a study using pulsed Doppler echocardiography combined with two-dimensional echocardiography (author's transl)].

Authors:  M Matsuda; Y Sugishita; T Yamaguchi; T Tamura; I Ito
Journal:  J Cardiogr       Date:  1981-06

5.  Transmission of ultrasonic contrast through the lungs.

Authors:  R S Meltzer; O E Sartorius; C T Lancée; P W Serruys; P D Verdouw; C E Essed; J Roelandt
Journal:  Ultrasound Med Biol       Date:  1981       Impact factor: 2.998

6.  Contrast echocardiographic features of pulmonary hypertension and regurgitation.

Authors:  G Gullace; M T Savoia; P Ravizza; V Locatelli; P Addamiano; C Ranzi
Journal:  Br Heart J       Date:  1981-10

7.  Hemodynamic determinants of pulmonary valve motion during systole in experimental pulmonary hypertension.

Authors:  M Tahara; H Tanaka; S Nakao; H Yoshimura; S Sakurai; C Tei; T Kashima
Journal:  Circulation       Date:  1981-12       Impact factor: 29.690

8.  Contrast echocardiographic evaluation of changes in flow velocity in the right side of the heart.

Authors:  A Shina; K Kondo; Y Nakasone; M Tsuchiya; T Yaginuma; S Hosoda
Journal:  Circulation       Date:  1981-06       Impact factor: 29.690

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.