Dialysis anaemia caused by subacute zinc toxicity.

J J Petrie, P G Row.   

Abstract

Nine out of ten patients dialysed in a satellite dialysis unit became severely anaemic over a 2-month period. The onset of anaemia coincided with the installation of a new galvanised-iron water softener in the dialysate water-supply system. An activated carbon filter was installed and haemoglobin levels returned towards previous values. Two patients on home dialysis showed similar falls in haemoglobin after the installation of galvanised iron piping in their dialysate water-supply systems; these problems also resolved after carbon filtration of the dialysis water. It is suggested that elution of zinc from galvanised iron can cause anaemia in dialysis patients. Carbon filtration removes of 95-99% of the zinc eluted.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 68277     DOI: 10.1016/s0140-6736(77)92718-0

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  6 in total

1.  Zinc again.

Authors:  S C Glover; M I White
Journal:  Br Med J       Date:  1977-09-03

2.  Ocular changes in patients undergoing long-term desferrioxamine treatment.

Authors:  G B Arden; B Wonke; C Kennedy; E R Huehns
Journal:  Br J Ophthalmol       Date:  1984-12       Impact factor: 4.638

3.  Relationship between haemodialysis anaemia and copper and zinc.

Authors:  S Hosokawa; H Nishitani; K Umemura; T Nishio; T Tomoyoshi; K Sawanishi; O Yoshida
Journal:  Int Urol Nephrol       Date:  1985       Impact factor: 2.370

Review 4.  Hemodialysis and water quality.

Authors:  Angela D Coulliette; Matthew J Arduino
Journal:  Semin Dial       Date:  2013 Jul-Aug       Impact factor: 3.455

5.  Influence of haemodialysis and renal transplantation on trace element concentrations in children with chronic renal failure.

Authors:  M Wihelm; B Hanewinckel; F Bläker
Journal:  Eur J Pediatr       Date:  1986-10       Impact factor: 3.183

6.  An outbreak of Heinz body positive hemolytic anemia in chronic hemodialysis patients.

Authors:  H J Pyo; Y J Kwon; K S Wee; S Y Kwon; C H Lee; S Kim; J S Lee; S H Cho; C W Cha
Journal:  Korean J Intern Med       Date:  1993-07       Impact factor: 2.884

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.