Literature DB >> 6824166

Evaluation of transesophageal Doppler detection of air embolism in dogs.

R W Martin, P S Colley.   

Abstract

The authors assessed the use of a cylindrical sensor which transceives (transmits and receives) ultrasound in a 360 degree arc mounted on a standard esophageal stethoscope catheter to detect air embolism in dogs. They used electronic circuitry developed specifically to provide a continuous analog recording of high frequency Doppler energy as well as an audible signal. They found that the esophageal Doppler sensor was easy to position. In 25 of 30 dogs, the system distinguished Doppler sounds of venous air emboli that were present either in the superior vena cava, right atrium, right ventricle, or pulmonary artery from normal cardiovascular sounds. In the remaining five animals, Doppler heart and air emboli sounds were initially of poor quality, but improved with aspiration of air from the esophagus. In another five dogs, arterial air emboli produced by left ventricular injections also were detected. The esophageal sensor was sensitive to both venous and arterial air emboli ranging from 0.05--0.2 ml of air, and the authors consistently detected repeated intravenous injections of air throughout a 5-h time period. Optimal position of the sensor for detection of venous air emboli was at the level of the superior vena cava above its junction with the right atrium. Optimal position to detect arterial air emboli introduced via a left ventricular catheter was at the level of the aortic arch. Tissue analysis of the esophagus revealed no morphologic damage due to the sensor or transmitted energy.

Entities:  

Mesh:

Year:  1983        PMID: 6824166     DOI: 10.1097/00000542-198302000-00003

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  5 in total

1.  Computer-assisted Doppler monitoring to enhance detection of air emboli.

Authors:  G L Gibby; G A Ghani
Journal:  J Clin Monit       Date:  1988-01

2.  Near fatal gas embolism during laparoscopic cholecystectomy.

Authors:  A U Khan; K Pandya; M A Clifton
Journal:  Ann R Coll Surg Engl       Date:  1995-01       Impact factor: 1.891

3.  Anesthesia for posterior fossa surgery in the sitting position.

Authors:  H C Tausk; R Miller
Journal:  Bull N Y Acad Med       Date:  1983-11

4.  Capnography in the early diagnosis of carbon dioxide embolism during laparoscopy.

Authors:  D Shulman; H B Aronson
Journal:  Can Anaesth Soc J       Date:  1984-07

5.  Transesophageal echocardiographic study of venous air embolism following pneumomediastinum in dogs.

Authors:  W P Morris; S J Allen; A S Tonnesen; B D Butler
Journal:  Intensive Care Med       Date:  1995-10       Impact factor: 17.440

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.