Literature DB >> 681410

ICLH arthroplasty of the knee: 1968--1977.

M A Freeman, R C Todd, P Bamert, W H Day.   

Abstract

The essentially satisfactory results from the ICLH implant as used until 1975 were marred by examples of loosening and sinking of the tibial implant, by patellar pain of varying severity, by wear of the tibial implant caused by fragments of cement and by failure consistently to control the alignment of the leg. This report describes the methods now being used to overcome these complications and gives an account of the success so far achieved.

Entities:  

Mesh:

Year:  1978        PMID: 681410     DOI: 10.1302/0301-620X.60B3.681410

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  28 in total

1.  Soft tissue balance measurement in minimal incision surgery compared to conventional total knee arthroplasty.

Authors:  Tomoyuki Matsumoto; Hirotsugu Muratsu; Seiji Kubo; Kiyonori Mizuno; Keisuke Kinoshita; Kazunari Ishida; Takehiko Matsushita; Ken Sasaki; Katsumasa Tei; Koji Takayama; Hiroshi Sasaki; Shinya Oka; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-08-03       Impact factor: 4.342

2.  The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement.

Authors:  Colin R Smith; Michael F Vignos; Rachel L Lenhart; Jarred Kaiser; Darryl G Thelen
Journal:  J Biomech Eng       Date:  2016-02       Impact factor: 2.097

3.  [What is the influence of the approach to intraoperative measurement of the knee joint on total knee arthroplasty? A navigation-controlled study on a cadaver knee].

Authors:  C Lüring; T Hüfner; D Kendoff; L Perlick; H Bäthis; J Grifka; C Krettek
Journal:  Unfallchirurg       Date:  2005-04       Impact factor: 1.000

Review 4.  [Advances in soft tissue management in total knee arthroplasty. The use of imageless navigation systems].

Authors:  C Lüring; L Perlick; M Tingart; H Bäthis; J Grifka
Journal:  Orthopade       Date:  2006-10       Impact factor: 1.087

5.  The influence of postoperative coronal alignment on revision surgery in total knee arthroplasty.

Authors:  Samer S Morgan; A Bonshahi; N Pradhan; A Gregory; A Gambhir; M L Porter
Journal:  Int Orthop       Date:  2007-07-05       Impact factor: 3.075

6.  Measurement of joint gap load in patella everted and reset position during total knee arthroplasty.

Authors:  Nobuyuki Yoshino; Nobuyoshi Watanabe; Yoshinobu Watanabe; Yukihisa Fukuda; Shinro Takai
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-11-08       Impact factor: 4.342

7.  Results of total knee replacement with/without resurfacing of the patella.

Authors:  Abdul Khan; Nikhil Pradhan
Journal:  Acta Ortop Bras       Date:  2012       Impact factor: 0.513

8.  Patellar fracture after replacement of the tibio-femoral joint with the ICLH prosthesis.

Authors:  M A Freeman; A Hammer
Journal:  Arch Orthop Trauma Surg       Date:  1978-08-11

9.  Patellofemoral function in total condylar knee arthroplasty.

Authors:  O Sneppen; G H Gudmundsson; C Bünger
Journal:  Int Orthop       Date:  1985       Impact factor: 3.075

10.  Utility of preoperative distractive stress radiograph for beginners to extent of medial release in total knee arthroplasty.

Authors:  Jae Ang Sim; Ji Hoon Kwak; Sang Hoon Yang; Sung Hoon Moon; Beom Koo Lee; Joon Yub Kim
Journal:  Clin Orthop Surg       Date:  2009-05-30
View more