Ozone decontamination of bioclean rooms.

T Masaoka, Y Kubota, S Namiuchi, T Takubo, T Ueda, H Shibata, H Nakamura, J Yoshitake, T Yamayoshi, H Doi, T Kamiki.   

Abstract

To establish a convenient method for decontaminating bioclean rooms, the effect of ozone at 80 mg/m3 for 72 h was compared with formaldehyde vaporization at an initial concentration of 150 mg/m3 with a gradual decrease to 20 mg/m3 during 72 h. Ozone was found to be inferior to formaldehyde in activity. When the bioclean room was decontaminated twice with ozone, the mean colony count per 10 cm2 was decreased to about the same level as when formaldehyde was used. Ozone had a strong caustic effect upon rubber materials. Despite these disadvantages, ozone decontamination was demonstrated to be superior to formaldehyde vaporization because of convenience, insignificant inhalation of the disinfectant by the hospital staff, and very rapid expulsion of the gas after ventilation. Because the disadvantages of ozone can be easily controlled, this study suggests that ozone decontamination is a promising method for maintaining bioclean rooms.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6803668      PMCID: PMC241865          DOI: 10.1128/aem.43.3.509-513.1982

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  4 in total

1.  Microbiological studies of a laminar air flow unit for patients.

Authors:  G P Bodey; B Gewertz
Journal:  Arch Environ Health       Date:  1969-12

2.  A note on a simple and rapid method of bacteriological sampling by means of agar sausages.

Authors:  L ten Cate
Journal:  J Appl Bacteriol       Date:  1965-08

3.  Adsorption of formaldehyde by various surfaces during gaseous decontamination.

Authors:  J R Braswell; D R Spiner; R K Hoffman
Journal:  Appl Microbiol       Date:  1970-11

4.  Patient protection in cancer chemotherapy.

Authors:  S A Schwartz; S Perry
Journal:  JAMA       Date:  1966-08-22       Impact factor: 56.272

  4 in total
  6 in total

1.  Liquid-phase study of ozone inactivation of Venezuelan equine encephalomyelitis virus.

Authors:  D H Akey; T E Walton
Journal:  Appl Environ Microbiol       Date:  1985-10       Impact factor: 4.792

Review 2.  Review of Decontamination Techniques for the Inactivation of Bacillus anthracis and Other Spore-Forming Bacteria Associated with Building or Outdoor Materials.

Authors:  Joseph P Wood; Alden Charles Adrion
Journal:  Environ Sci Technol       Date:  2019-04-02       Impact factor: 9.028

3.  Ozone killing action against bacterial and fungal species; microbiological testing of a domestic ozone generator.

Authors:  A Dyas; B J Boughton; B C Das
Journal:  J Clin Pathol       Date:  1983-10       Impact factor: 3.411

4.  The use of ozone gas for the inactivation of Bacillus anthracis and Bacillus subtilis spores on building materials.

Authors:  Joseph P Wood; Morgan Wendling; William Richter; James Rogers
Journal:  PLoS One       Date:  2020-05-21       Impact factor: 3.240

5.  The microbial killing capacity of aqueous and gaseous ozone on different surfaces contaminated with dairy cattle manure.

Authors:  Ameer Megahed; Brian Aldridge; James Lowe
Journal:  PLoS One       Date:  2018-05-14       Impact factor: 3.240

6.  Detrimental Effect of Ozone on Pathogenic Bacteria.

Authors:  Karyne Rangel; Fellipe O Cabral; Guilherme C Lechuga; João P R S Carvalho; Maria H S Villas-Bôas; Victor Midlej; Salvatore G De-Simone
Journal:  Microorganisms       Date:  2021-12-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.