Relation between pressure difference across the aortic valve and left ventricular outflow.

C Clark.   

Abstract

Equations are presented to relate left ventricular-aortic pressure difference and flow. The relative importance of fluid inertia and friction are evaluated and the errors introduced by the neglect of compliance are estimated. The equations are used to calculate pressure differences for both normal conditions and simulated aortic stenosis and to explain the timing of the reversal of the pressure difference.

Entities:  

Mesh:

Year:  1978        PMID: 679227     DOI: 10.1093/cvr/12.5.276

Source DB:  PubMed          Journal:  Cardiovasc Res        ISSN: 0008-6363            Impact factor:   10.787


  5 in total

1.  Derivation of a simplified relation for assessing aortic root pressure drop incorporating wall compliance.

Authors:  Hossein Mohammadi; Raymond Cartier; Rosaire Mongrain
Journal:  Med Biol Eng Comput       Date:  2014-11-28       Impact factor: 2.602

2.  The impact of the aortic valve impairment on the distant coronary arteries hemodynamics: a fluid-structure interaction study.

Authors:  Hossein Mohammadi; Raymond Cartier; Rosaire Mongrain
Journal:  Med Biol Eng Comput       Date:  2017-03-18       Impact factor: 2.602

3.  Hydraulic orifice formula for echographic measurement of the mitral valve area in stenosis. Application to M-mode echocardiography and correlation with cardiac catheterisation.

Authors:  W S Seitz; K Furukawa
Journal:  Br Heart J       Date:  1981-07

Review 4.  MRI Assessment of Diastolic and Systolic Intraventricular Pressure Gradients in Heart Failure.

Authors:  Snigdha Jain; Francisco J Londono; Patrick Segers; Thierry C Gillebert; Marc De Buyzere; Julio A Chirinos
Journal:  Curr Heart Fail Rep       Date:  2016-02

5.  One-point carotid wave intensity predicts cardiac mortality in patients with congestive heart failure and reduced ejection fraction.

Authors:  Olga Vriz; Marco Pellegrinet; Concetta Zito; Vitantonio di Bello; Manola Bettio; Scipione Carerj; Antonello Cittadini; Eduardo Bossone; Francesco Antonini-Canterin
Journal:  Int J Cardiovasc Imaging       Date:  2015-06-23       Impact factor: 2.357

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.