Literature DB >> 6792235

Slice-thickness artifacts in gray-scale ultrasound.

A Goldstein, B L Madrazo.   

Abstract

We have become increasingly aware of the presence of a type of image artifact normally appearing in anechoic areas (eg, cyst, bladder, gallbladder) and giving the appearance of "sludge" or "debris." These artifactual echoes may be caused by the fact that the finite width of the transducer beam pattern produces a finite thickness of the patient scan plane. All echoes produced in this "thick" scan plane are misinterpreted as being due to structures in the normally assumed "thin" scan plane. We have tested and verified this hypothesis by simulating soft tissue interfaces with 400 grit silicon carbide sandpaper in a water tank. A set of clues are proposed to enable the rapid identification of these artifacts.

Entities:  

Mesh:

Year:  1981        PMID: 6792235     DOI: 10.1002/jcu.1870090704

Source DB:  PubMed          Journal:  J Clin Ultrasound        ISSN: 0091-2751            Impact factor:   0.910


  8 in total

1.  Ultrasound super-resolution imaging provides a noninvasive assessment of renal microvasculature changes during mouse acute kidney injury.

Authors:  Qiyang Chen; Jaesok Yu; Brittney M Rush; Sean D Stocker; Roderick J Tan; Kang Kim
Journal:  Kidney Int       Date:  2020-03-03       Impact factor: 10.612

2.  The value of dynamic imaging for standardization of abdominal ultrasonography.

Authors:  Sachiyo Inamura; Fumio Tsujimoto; Takanori Okamura; Masaru Sakurai; Shinichi Nakaya; Osamu Ishii; Sachihiko Nobuoka; Takahide Matsuda
Journal:  J Med Ultrason (2001)       Date:  2012-01-21       Impact factor: 1.314

3.  SLIDE: automatic spine level identification system using a deep convolutional neural network.

Authors:  Jorden Hetherington; Victoria Lessoway; Vit Gunka; Purang Abolmaesumi; Robert Rohling
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-03-30       Impact factor: 2.924

Review 4.  Fact or Artifact in Two-Dimensional Echocardiography: Avoiding Misdiagnosis and Missed Diagnosis.

Authors:  Philippe B Bertrand; Robert A Levine; Eric M Isselbacher; Pieter M Vandervoort
Journal:  J Am Soc Echocardiogr       Date:  2016-03-09       Impact factor: 5.251

5.  Ultrasonography of the gallbladder in pregnancy.

Authors:  E Bartoli; N Calonaci; R Nenci
Journal:  Gastrointest Radiol       Date:  1984

6.  Optimal site for ultrasound-guided venous catheterisation in paediatric patients: an observational study to investigate predictors for catheterisation success and a randomised controlled study to determine the most successful site.

Authors:  Jun Takeshita; Yoshinobu Nakayama; Yasufumi Nakajima; Daniel I Sessler; Satoru Ogawa; Teiji Sawa; Toshiki Mizobe
Journal:  Crit Care       Date:  2015-01-20       Impact factor: 9.097

7.  Main Uncertainties in the RF Ultrasound Scanning Simulation of the Standard Ultrasound Phantoms.

Authors:  Monika Makūnaitė; Rytis Jurkonis; Arūnas Lukoševičius; Mindaugas Baranauskas
Journal:  Sensors (Basel)       Date:  2021-06-28       Impact factor: 3.576

8.  Dynamic needle tip positioning versus the angle-distance technique for ultrasound-guided radial artery cannulation in adults: a randomized controlled trial.

Authors:  Bing Bai; Yuan Tian; Yuelun Zhang; Chunhua Yu; Yuguang Huang
Journal:  BMC Anesthesiol       Date:  2020-09-14       Impact factor: 2.217

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.