To determine how closely peak expired PCO2 measured by mass spectrometry reflects arterial PCO2 during anesthesia and what variables contribute to a difference between the two measurements, peak expired CO2, arterial PCO2, and other physiologic variables were measured simultaneously. There was a significant correlation between peak expired and arterial PCO2 (p less than 0.001). The difference between temperature-corrected arterial and peak expired PCO2 was related to the presence or absence of lung disease, age, A.S.A. class, and systolic blood pressure. No significant relationship was seen between the temperature-corrected difference and duration of anesthesia, diastolic pressure, expired O2 concentration, or anesthetic agent. Mean temperature-corrected arterial PCO2 exceeded mean peak expired PCO2 by 1.7 torr in all patients, 0.8 torr in patients without lung disease, and 3.3 torr in patients with lung disease. In patients in whom more than one arterial sample was obtained, initial differences correlated significantly with subsequent differences (p less than 0.001).

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 6787952

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  37 in total

Review 1.  Non-invasive monitoring of carbon-dioxide in newborns and children.

Authors:  S Dutta
Journal:  Indian J Pediatr       Date:  1999 Jan-Feb       Impact factor: 1.967

2.  Clinical validation of a digital transcutaneous PCO2/SpO2 ear sensor in adult patients after cardiac surgery.

Authors:  Werner Baulig; Philipp Schütt; Hans R Roth; Josef Hayoz; Edith R Schmid
Journal:  J Clin Monit Comput       Date:  2007-08-16       Impact factor: 2.502

3.  Comparison of neurologic responses to the use of medetomidine as a sole agent or preanesthetic in laboratory beagles.

Authors:  C E Short; J E Räihä; M P Räihä; K Otto
Journal:  Acta Vet Scand       Date:  1992       Impact factor: 1.695

4.  Variability of blood gases, pulse oximeter saturation, and end-tidal carbon dioxide pressure in stable, mechanically ventilated trauma patients.

Authors:  D Hess; N N Agarwal
Journal:  J Clin Monit       Date:  1992-04

5.  Stability of arterial to end-tidal carbon dioxide gradients during postoperative cardiorespiratory support.

Authors:  G B Russell; J M Graybeal; J C Strout
Journal:  Can J Anaesth       Date:  1990-07       Impact factor: 5.063

6.  End tidal carbon dioxide as a predictor of the arterial PCO2 in the emergency department setting.

Authors:  C Yosefy; E Hay; Y Nasri; E Magen; L Reisin
Journal:  Emerg Med J       Date:  2004-09       Impact factor: 2.740

7.  Noninvasive monitoring of carbon dioxide: a comparison of the partial pressure of transcutaneous and end-tidal carbon dioxide with the partial pressure of arterial carbon dioxide.

Authors:  C Q Phan; K K Tremper; S E Lee; S J Barker
Journal:  J Clin Monit       Date:  1987-07

8.  Haemodynamic and ventilatory changes during laparoscopic cholecystectomy in elderly ASA III patients.

Authors:  K Dhoste; L Lacoste; J Karayan; M S Lehuede; D Thomas; J Fusciardi
Journal:  Can J Anaesth       Date:  1996-08       Impact factor: 5.063

Review 9.  Misleading end-tidal CO2 tensions.

Authors:  R W Wahba; M J Tessler
Journal:  Can J Anaesth       Date:  1996-08       Impact factor: 5.063

10.  The correlation and level of agreement between end-tidal and blood gas pCO2 in children with respiratory distress: a retrospective analysis.

Authors:  James M Moses; Jamin L Alexander; Michael Sd Agus
Journal:  BMC Pediatr       Date:  2009-03-12       Impact factor: 2.125

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.