Literature DB >> 677561

Transcutaneous oxygen tension in sick infants.

J L Peabody, G A Gregory, M M Willis, W H Tooley.   

Abstract

The clinical usefulness of the transcutaneous O2 electrode was investigated in 30 sick infants; 159 simultaneous measurements of arterial PO2 and transcutaneous PO2 were made. During the comparisons, arterial blood pressure, heart rate, and thoracic impedance were continuously recorded, and skin axillary and environmental temperatures and hematocrit were noted. Despite a wide range of arterial blood pressure and hematocrits, arterial PO2 and transcutaneous PO2 were similar (slope, 0.963), except for 2 groups of sick infants. Some infants with severe, persistent pulmonary hypertension who were receiving an intravascular infusion of tolazoline and infants with mean arterial blood pressures more than 2.5 SD less than the predicted average had values for transcutaneous PO2 that were lower than PO2. The surface O2 electrode is safe and relatively easy to use and provides data that can help in the management of most sick infants.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 677561     DOI: 10.1164/arrd.1978.118.1.83

Source DB:  PubMed          Journal:  Am Rev Respir Dis        ISSN: 0003-0805


  8 in total

Review 1.  Non-invasive monitoring in the pediatric ICU, Part I: Transcutaneous oxygen monitoring (PtcO2).

Authors:  T Ravindranath
Journal:  Indian J Pediatr       Date:  1990 Mar-Apr       Impact factor: 1.967

2.  Transcutaneous oxygen monitoring in an infant undergoing tracheoesophageal fistula repair.

Authors:  M J Bautista; B S Kuwahara; C U Henderson
Journal:  Can Anaesth Soc J       Date:  1986-07

3.  Current considerations in neonatal anaesthesia.

Authors:  R Waugh; G G Johnson
Journal:  Can Anaesth Soc J       Date:  1984-11

4.  In vivo response time of transcutaneous oxygen measurement to changes in inspired oxygen in normal adults.

Authors:  J T Brown; M S Schur; B C McClain; E R Kafer
Journal:  Can Anaesth Soc J       Date:  1984-01

5.  Pulse oximetry for early detection of hypoxemia in anesthetized infants.

Authors:  T D Brooks; N Gravenstein
Journal:  J Clin Monit       Date:  1985-04

6.  Estimation of arterial oxygen tension in adult subjects using a transcutaneous electrode.

Authors:  D C Hutchison; G Rocca; D Honeybourne
Journal:  Thorax       Date:  1981-06       Impact factor: 9.139

7.  Transcutaneous PO2 monitoring in infants with cyanotic congenital heart disease treated with prostaglandin E1.

Authors:  K J Kimble; R L Ariagno; P Pitlick
Journal:  Pediatr Cardiol       Date:  1983 Apr-Jun       Impact factor: 1.655

8.  Transcutaneous carbon dioxide and oxygen tension in newborn infants: reliability of a combined monitor of oxygen tension and carbon dioxide tension.

Authors:  S Fanconi; H Sigrist
Journal:  J Clin Monit       Date:  1988-04
  8 in total