Correction for gas compression in mechanical ventilators.

A F Forbat, C Her.   

Abstract

Errors in measurements arising from compression of gases in a mechanical ventilator may be corrected by calculation based on the compressible volume of the ventilator, or by physical separation of expired from compressed gases. Using a Frumin valve to effect this separation, the volume compressed in the Bear I ventilator was found to be 5.15 ml/mm Hg, and its compressible volume to be 3790 ml (range 3760 to 3806 ml). The ratio of uncorrected/corrected tidal volume (termed the correction factor) was 1.229 +/- 0.014. When VD/VT was corrected using this factor and compared with that obtained by calculating VD/VT using PECO2 measurements in expired air collected from the Frumin valve, the difference between the two was not significant. It is concluded that the use of the Frumin valve is a practical method for determining the true dead space-to-tidal volume ratios and that the application of the correction factor is also reliable.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 6773435

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  6 in total

1.  Bench test evaluation of volume delivered by modern ICU ventilators during volume-controlled ventilation.

Authors:  Aissam Lyazidi; Arnaud W Thille; Guillaume Carteaux; Fabrice Galia; Laurent Brochard; Jean-Christophe M Richard
Journal:  Intensive Care Med       Date:  2010-09-23       Impact factor: 17.440

Review 2.  Deadspace ventilation: a waste of breath!

Authors:  Pratik Sinha; Oliver Flower; Neil Soni
Journal:  Intensive Care Med       Date:  2011-03-11       Impact factor: 17.440

3.  Positive end-expiratory pressure and lung compliance: effect on delivered tidal volume.

Authors:  P H Pan; J J van der Aa
Journal:  Can J Anaesth       Date:  1995-09       Impact factor: 5.063

4.  Comparison of volumetric capnography and mixed expired gas methods to calculate physiological dead space in mechanically ventilated ICU patients.

Authors:  Pratik Sinha; Neil Soni
Journal:  Intensive Care Med       Date:  2012-08-15       Impact factor: 17.440

5.  Tidal volume changes due to the interaction of anesthesia machine and anesthesia ventilator.

Authors:  N Gravenstein; M J Banner; G McLaughlin
Journal:  J Clin Monit       Date:  1987-07

6.  Assessment of dead-space ventilation in patients with acute respiratory distress syndrome: a prospective observational study.

Authors:  Jonne Doorduin; Joeke L Nollet; Manon P A J Vugts; Lisanne H Roesthuis; Ferdi Akankan; Johannes G van der Hoeven; Hieronymus W H van Hees; Leo M A Heunks
Journal:  Crit Care       Date:  2016-05-05       Impact factor: 9.097