Clinical studies of gas exchange during ventilatory support--a method using the Siemens-Elema CO2 analyzer.

S G Olsson, R Fletcher, B Jonson, L Nordstöm, O Prakash.   

Abstract

We describe a new portable infra-red analyses for use with the Siemens-Elema Servo ventilator. The sensor head constitutes a Y-piece connecting the patient to the ventilator tubing, and gives instant carbon dioxide determination. It is based upon simple principles that can be realized with modern techniques, offering for instance freedom from interference by anaesthetic gases, and eliminating the need for calibration. A non-zero inspired carbon dioxide concentration interferes with the measurements. Integration of the carbon dioxide signal with the flow signal from the Servo ventilator yields data about carbon dioxide excretion, and additional calculation yields VD/VT if PaCO2 is known. The accuracy of determination of end-tidal carbon dioxide and carbon dioxide elimination was found to be adequate for research purposes, and that of VD/VT for clinical purposes. The device is considered to be of value in the operating theatre and intensive care unit, for monitoring, as a guide to ventilatory needs, and for the investigation of the magnitude and causes of increased deadspace.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 6770881     DOI: 10.1093/bja/52.5.491

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  14 in total

Review 1.  Capnometry and anaesthesia.

Authors:  K Bhavani-Shankar; H Moseley; A Y Kumar; Y Delph
Journal:  Can J Anaesth       Date:  1992-07       Impact factor: 5.063

2.  Model fitting of volumetric capnograms improves calculations of airway dead space and slope of phase III.

Authors:  Gerardo Tusman; Adriana Scandurra; Stephan H Böhm; Fernando Suarez-Sipmann; Fernando Clara
Journal:  J Clin Monit Comput       Date:  2009-06-11       Impact factor: 2.502

3.  Ultrasound-spirometry and capnography in horses: analysis of measurement reliability.

Authors:  C Herholz; R Straub; A Busato
Journal:  Vet Res Commun       Date:  2001-02       Impact factor: 2.459

4.  Prototype ventilator and alarm algorithm for the NASA space station.

Authors:  J X Brunner; D R Westenskow; P Zelenkov
Journal:  J Clin Monit       Date:  1989-04

5.  Physiological dead space during general anaesthesia for Caesarean section.

Authors:  K B Shankar; H Moseley; V Vemula; Y Kumar
Journal:  Can J Anaesth       Date:  1987-07       Impact factor: 5.063

Review 6.  Monitoring of lung function in acute respiratory distress syndrome.

Authors:  Anders Larsson; Claude Guerin
Journal:  Ann Transl Med       Date:  2017-07

7.  A new calibration method that compensates for the effects of O2 and N2 on infrared CO2 analysers.

Authors:  Yongquan Tang; Martin J Turner; A Barry Baker
Journal:  J Clin Monit Comput       Date:  2006-06-08       Impact factor: 2.502

8.  Respiratory function and carbonic anhydrase inhibition.

Authors:  P G Berthelsen; J O Dich-Nielsen
Journal:  Intensive Care Med       Date:  1987       Impact factor: 17.440

9.  Non-invasive pulmonary blood flow measurement by means of CO2 analysis of expiratory gases.

Authors:  R J Bosman; C P Stoutenbeek; D F Zandstra
Journal:  Intensive Care Med       Date:  1991       Impact factor: 17.440

10.  Noninvasive recovery of acinar anatomic information from CO2 expirograms.

Authors:  J D Schwardt; G R Neufeld; J E Baumgardner; P W Scherer
Journal:  Ann Biomed Eng       Date:  1994 May-Jun       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.