Literature DB >> 6768244

Radiologic follow-up of vena cava filter devices.

L L Berland, F E Maddison, V M Bernhard.   

Abstract

A total of 66 vena cava filters was implanted to prevent pulmonary emboli: 33 Mobin-Uddin umbrellas and 33 Kim-Ray-Greenfield devices. Radiologic examinations were available in 59 patients, 37 having one or more follow-up studies. Most of the Mobin-Uddin umbrellas became thrombosed. Although most Kim-Ray-Greenfield devices remained patent, some migrated, and several penetrated the cava wall; this latter finding can be diagnosed on plain films. Neither of these devices is fully safe nor effective in preventing pulmonary emboli; further improvements are needed.

Entities:  

Mesh:

Year:  1980        PMID: 6768244     DOI: 10.2214/ajr.134.5.1047

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  8 in total

1.  Recurrent pulmonary embolism after inferior vena caval interruption with a Greenfield filter.

Authors:  W E Richenbacher; R G Atnip; D B Campbell; J A Waldhausen
Journal:  World J Surg       Date:  1989 Sep-Oct       Impact factor: 3.352

2.  Caval umbrella causing obstructive uropathy.

Authors:  D Flanagan; T Creasy; F Chataway; D Kerr
Journal:  Postgrad Med J       Date:  1996-04       Impact factor: 2.401

3.  Biometry of infrarenal inferior vena cava measured by cavography. Clinical applications.

Authors:  P Bonnichon; F Gaudard; E Ouakil; P Lebozec; C de Labrouhe; A Bonnin; C Aaron; Y Chapuis
Journal:  Surg Radiol Anat       Date:  1989       Impact factor: 1.246

4.  Late Greenfield filter vena cava perforation causing a small bowel obstruction: case report.

Authors:  A Dagirmanjian; I Beckman
Journal:  Cardiovasc Intervent Radiol       Date:  1990 Feb-Mar       Impact factor: 2.740

5.  The Kimray-Greenfield vena cava filter: a case of unusual misplacement.

Authors:  H A Allen; S J Cisternino; O E Ottesen; L Queral; F Dagher
Journal:  Cardiovasc Intervent Radiol       Date:  1982       Impact factor: 2.740

6.  A complication following Kimray-Greenfield filter insertion.

Authors:  B Leiter; J Sequeira; A F Weitzman; J Menzoian
Journal:  Cardiovasc Intervent Radiol       Date:  1981       Impact factor: 2.740

7.  Practical points on transvenous insertion of inferior vena cava filters.

Authors:  R A Novelline
Journal:  Cardiovasc Intervent Radiol       Date:  1980       Impact factor: 2.740

8.  Incomplete opening of an ALN-type inferior vena cava filter due to entanglement of the filter legs resulting in filter migration and inferior vena cava perforation.

Authors:  Satoshi Shimoo; Masahiro Koide
Journal:  Radiol Case Rep       Date:  2020-06-15
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.