Literature DB >> 6767854

Small bowel obstruction due to gaseous distention of an intestinal balloon.

S K Iyer, K L Chandrasekhara, T S Narayanaswamy.   

Abstract

A case of small bowel obstruction caused by inflation of a sealed, mercury-filled finger cot tipped feeder catheter, used for enteral alimentation, is reported. The patient had infrapapillary duodenal obstruction, secondary to the intramural hematoma caused by blunt abdominal injury. The patient underwent surgery for the obstruction and the distended finger cot was decompressed. The mechanisms for such distention are discussed.

Entities:  

Mesh:

Year:  1980        PMID: 6767854      PMCID: PMC2552429     

Source DB:  PubMed          Journal:  J Natl Med Assoc        ISSN: 0027-9684            Impact factor:   1.798


  4 in total

1.  Complication of prolonged intestinal intubation: gaseous distention of the terminal balloon.

Authors:  J Rozanski; M Kleinfeld
Journal:  Am J Dig Dis       Date:  1975-11

2.  Diagnosis and treatment of pancreatic and duodenal injury.

Authors:  C E Lucas
Journal:  Surg Clin North Am       Date:  1977-02       Impact factor: 2.741

3.  Traumatic duodenal injuries: an analysis of 32 cases.

Authors:  N M Matolo; S E Cohen; A P Fontanetta; E F Wolfman
Journal:  Am Surg       Date:  1975-06       Impact factor: 0.688

4.  Hazardous gaseous distention of intestinal ballons.

Authors:  F J Fricke; M A Niewodowski
Journal:  JAMA       Date:  1976-06-14       Impact factor: 56.272

  4 in total