Enhancement of recovery of Legionella pneumophila from contaminated respiratory tract specimens by heat.

P H Edelstein, J B Snitzer, J A Bridge.   

Abstract

Heating of Legionella pneumophila and other Legionella spp. was studied to determine whether this technique could be used as a selective technique with contaminated clinical specimens. Studies of 13 different strains of Legionella spp. showed heterogeneous heat survival; heating at 60 degrees C for 1 to 2 min did not affect the survival of the majority of strains. Heating of four Pseudomonas aeruginosa strains at 60 degrees C for 2 min reduced bacterial counts by 98% or greater. Enterococci were heat tolerant, with virtually no inhibition under the same conditions. No inoculum effect was noted for any of the organisms tested. Heating of eight contaminated clinical specimens before plating on buffered charcoal-yeast extract medium reduced the numbers of contaminants on most plates but increased by only one the number of specimens yielding L. pneumophila. Plating the same specimens on selective media with or without heat pretreatment yielded L. pneumophila in every case. Heating of clinical specimens at 60 degrees C for 1 to 2 min before plating may occasionally increase the recovery of L. pneumophila from contaminated specimens, but this technique should not be generally used.

Entities:  

Mesh:

Year:  1982        PMID: 6761358      PMCID: PMC272540          DOI: 10.1128/jcm.16.6.1061-1065.1982

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  11 in total

1.  Detection of Legionnaires disease bacteria by direct immunofluorescent staining.

Authors:  W B Cherry; B Pittman; P P Harris; G A Hebert; B M Thomason; L Thacker; R E Weaver
Journal:  J Clin Microbiol       Date:  1978-09       Impact factor: 5.948

2.  Isolation of Legionella pneumophila from a transtracheal aspirate.

Authors:  P H Edelstein; S M Finegold
Journal:  J Clin Microbiol       Date:  1979-03       Impact factor: 5.948

3.  Legionella pneumophila in water plumbing systems.

Authors:  P J Dennis; J A Taylor; R B Fitzgeorge; C L Bartlett; G I Barrow
Journal:  Lancet       Date:  1982-04-24       Impact factor: 79.321

4.  Use of a semiselective medium to culture Legionella pneumophila from contaminated lung specimens.

Authors:  P H Edelstein; S M Finegold
Journal:  J Clin Microbiol       Date:  1979-08       Impact factor: 5.948

5.  Multiplication of Legionella pneumophila in unsterilized tap water.

Authors:  R B Yee; R M Wadowsky
Journal:  Appl Environ Microbiol       Date:  1982-06       Impact factor: 4.792

6.  Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures.

Authors:  R M Wadowsky; R B Yee; L Mezmar; E J Wing; J N Dowling
Journal:  Appl Environ Microbiol       Date:  1982-05       Impact factor: 4.792

7.  Laboratory diagnosis of Legionnaires' disease.

Authors:  P H Edelstein; R D Meyer; S M Finegold
Journal:  Am Rev Respir Dis       Date:  1980-02

8.  Ecological distribution of Legionella pneumophila.

Authors:  C B Fliermans; W B Cherry; L H Orrison; S J Smith; D L Tison; D H Pope
Journal:  Appl Environ Microbiol       Date:  1981-01       Impact factor: 4.792

9.  Improved semiselective medium for isolation of Legionella pneumophila from contaminated clinical and environmental specimens.

Authors:  P H Edelstein
Journal:  J Clin Microbiol       Date:  1981-09       Impact factor: 5.948

10.  Charcoal-yeast extract agar: primary isolation medium for Legionella pneumophila.

Authors:  J C Feeley; R J Gibson; G W Gorman; N C Langford; J K Rasheed; D C Mackel; W B Baine
Journal:  J Clin Microbiol       Date:  1979-10       Impact factor: 5.948

View more
  12 in total

1.  Rapid identification of legionellae by a colony blot assay based on a genus-specific monoclonal antibody.

Authors:  I Steinmetz; C Rheinheimer; D Bitter-Suermann
Journal:  J Clin Microbiol       Date:  1992-04       Impact factor: 5.948

Review 2.  Diagnosis of Legionella infection in Legionnaires' disease.

Authors:  J W Den Boer; E P F Yzerman
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2004-12       Impact factor: 3.267

3.  Legionella pneumophila in a hospital in Torino, Italy. A retrospective one-year study.

Authors:  A Moiraghi Ruggenini; M Castellani Pastoris; P J Dennis; C Barral; A Sciacovelli; F Carle; M Bolgiani; G Passarino; M G Mingrone; C Passi
Journal:  Epidemiol Infect       Date:  1989-02       Impact factor: 2.451

4.  Rapid detection and identification of Legionella pneumophila by a membrane immunoassay.

Authors:  A Bérubé; M Trudel; P Payment
Journal:  Appl Environ Microbiol       Date:  1989-06       Impact factor: 4.792

5.  Environmental Legionella.

Authors: 
Journal:  CMAJ       Date:  1985-12-15       Impact factor: 8.262

6.  Identification of 22 Legionella species and 33 serogroups with the slide agglutination test.

Authors:  W L Thacker; B B Plikaytis; H W Wilkinson
Journal:  J Clin Microbiol       Date:  1985-05       Impact factor: 5.948

7.  DNA polymorphisms in strains of Legionella pneumophila serogroups 3 and 4 detected by macrorestriction analysis and their use for epidemiological investigation of nosocomial legionellosis.

Authors:  P C Lück; J Köhler; M Maiwald; J H Helbig
Journal:  Appl Environ Microbiol       Date:  1995-05       Impact factor: 4.792

Review 8.  Legionella and Legionnaires' disease: 25 years of investigation.

Authors:  Barry S Fields; Robert F Benson; Richard E Besser
Journal:  Clin Microbiol Rev       Date:  2002-07       Impact factor: 26.132

9.  DNA probe specific for Legionella pneumophila.

Authors:  P A Grimont; F Grimont; N Desplaces; P Tchen
Journal:  J Clin Microbiol       Date:  1985-03       Impact factor: 5.948

10.  Epidemiological and environmental investigations of Legionella pneumophila infection in cattle and case report of fatal pneumonia in a calf.

Authors:  M Fabbi; M C Pastoris; E Scanziani; S Magnino; L Di Matteo
Journal:  J Clin Microbiol       Date:  1998-07       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.