Literature DB >> 6745599

Endoscopical determination of gastric mucosal blood flow by the crossed thermocouple method.

A Hiramatsu, T Watanabe, M Okuhira, S Uchiyama, T Mizuno, Y Sameshima.   

Abstract

A crossed thermocouple method in combination with endoscopy was applied to determine the blood flow rate of the human gastric mucosa. Determination was carried out with 11 healthy control subjects at 8 sites of the stomach. The blood flow rates at all sites in the corpus were found to be higher than those at the antrum. In subjects less than 50 years old the blood flow rate in the corpus was higher than in older subjects. These results were in agreed well with those obtained by the hydrogen gas clearance method, which is widely adopted clinically. The crossed thermocouple method is easily applicable to all sites in the gastric mucosa and the time required for the assay is very short. This method dose not require the inhalation of hydrogen gas which is necessary for the hydrogen gas clearance method and which is possibly harmful to humans. Although the values obtained by the crossed thermocouple method are relative to the value at a certain fixed site, this method will holds great potential for the determination of gastric mucosal blood flow rate.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6745599     DOI: 10.1007/BF02779172

Source DB:  PubMed          Journal:  Gastroenterol Jpn        ISSN: 0435-1339


  7 in total

1.  GASTRIC BLOOD FLOW AND INHIBITION OF HISTAMINE-STIMULATED GASTRIC SECRETION. OCCURRENCE FOLLOWING POSTERIOR HYPOTHALAMIC STIMULATION.

Authors:  A S LEONARD; J C ENGLE; E T PETER; D LONG; O H WANGENSTEEN
Journal:  JAMA       Date:  1964-02-22       Impact factor: 56.272

2.  MEASUREMENT OF LOCAL BLOOD FLOW WITH HYDROGEN GAS.

Authors:  K AUKLAND; B F BOWER; R W BERLINER
Journal:  Circ Res       Date:  1964-02       Impact factor: 17.367

3.  The gastric secretion of drugs: a pH partition hypothesis.

Authors:  P A SHORE; B B BRODIE; C A HOGBEN
Journal:  J Pharmacol Exp Ther       Date:  1957-03       Impact factor: 4.030

4.  [Continuous registration of muscular circulation in man with a calorimeter catheter].

Authors:  H HENSEL; J RUEF; K GOLENHOFEN
Journal:  Pflugers Arch Gesamte Physiol Menschen Tiere       Date:  1954

5.  Internal calorimetry in the determination of thermal conductivity and blood flow.

Authors:  J GRAYSON
Journal:  J Physiol       Date:  1952-09       Impact factor: 5.182

6.  Contact electrode method in hydrogen gas clearance technique: a new method for determination of regional gastric mucosal blood flow in animals and humans.

Authors:  M Murakami; M Moriga; T Miyake; H Uchino
Journal:  Gastroenterology       Date:  1982-03       Impact factor: 22.682

7.  Gastric mucosal blood-flow in the dog measured by clearance of krypton 85--the response to histamine.

Authors:  P R Bell; C Battersby; A M Harper
Journal:  Br J Surg       Date:  1967-12       Impact factor: 6.939

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.