Literature DB >> 6744561

The problem of cardiac valve prostheses, anticoagulants, and pregnancy.

E Salazar, A Zajarias, N Gutierrez, I Iturbe.   

Abstract

To assess the maternal and fetal risks in patients with cardiac valve prostheses, a series of 223 pregnancies in 156 women was studied. In 68 pregnancies (group I) treatment with antiplatelet agents was substituted for that with coumarinics from the first trimester on. Group II (128 pregnancies) received coumarinics through the thirty-eighth week of gestation. Three patients in group I died as a result of thrombosis of their caged-ball valves. The incidence of cerebral embolism was 25.0% in group I and 2.3% in group II patients, while that of spontaneous abortion was 10.3% and 28.1%, respectively. Coumarin embryopathy was found in 7.9% of group II infants. Fetal death did not occur in the 12 cases in which subcutaneous heparin was substituted for the coumarin derivative in the first trimester and the last 2 weeks of pregnancy (group III), but maternal cerebral embolism developed in 8.3% of the patients. Finally, uneventful pregnancies and deliveries were observed in 12 of 15 mothers (group IV) with biological prostheses who received no anticoagulants. It is concluded that (1) women with cardiac valve prostheses should be counseled against becoming pregnant, (2) antiplatelet agents do not provide protection against thromboembolism in these patients, (3) because of the high incidence of fetal death and birth defects use of coumarinics is contraindicated in the first trimester and the last weeks of pregnancy, (4) the substitution of heparin at these times may decrease the incidence of these complications, and (5) bioprostheses are indicated in women who wish to bear children.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6744561

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  4 in total

Review 1.  Pregnancy in adult congenital heart disease.

Authors:  J W Roos-Hesselink; P T E Ruys; M R Johnson
Journal:  Curr Cardiol Rep       Date:  2013-09       Impact factor: 2.931

Review 2.  Antithrombotic therapy for prosthetic valves: routine treatment and special considerations.

Authors:  A M Al-Ahmad; D Hartnett-Daudelin; D N Salem
Journal:  Curr Cardiol Rep       Date:  2001-01       Impact factor: 2.931

3.  Pregnancy and the various forms of the Fontan circulation.

Authors:  Fiona Walker
Journal:  Heart       Date:  2006-10-11       Impact factor: 5.994

Review 4.  "Bridging" therapy with low molecular weight heparin in pregnant patients and patients with mechanical prosthetic heart valves.

Authors:  James B Groce
Journal:  J Thromb Thrombolysis       Date:  2003 Aug-Oct       Impact factor: 2.300

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.