Literature DB >> 6741648

Recoiling suture and methylmethacrylate in aneurysm thrombosis. Preliminary report.

A Patil, M P Nagaraj.   

Abstract

Injection of acrylic material into the aneurysm is a relatively simple procedure if escape of the material into the circulation can be prevented by means of a coil inserted into the aneurysm prior to injection of the acrylic material. In the present study, polypropylene (00000) suture was given a coiling property. On extrusion through a 22 gauge spinal needle the suture regained its coiled shape. Experiments were carried out on dogs with the external carotid artery serving as a model for an aneurysm. Using a 22 gauge spinal needle, first the coiled suture was inserted into the aneurysm and then methylmethacrylate was injected. Ten aneurysms were thrombosed. None of the animals suffered a neurological deficit. Complete thrombosis of the aneurysms were noted in all the animals. On perfection, this technique could eventually be used for stereotaxic thrombosis of intracranial aneurysms.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6741648     DOI: 10.1007/BF01406815

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  7 in total

1.  Cardiovascular effects of implanted acrylic bone cement.

Authors:  H Phillips; P V Cole; A W Lettin
Journal:  Br Med J       Date:  1971-08

2.  Mechanical devices for arterial occlusion.

Authors:  C Gianturco; J H Anderson; S Wallace
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1975-07

3.  Polyvinyl alcohol (Ivalon)--a new embolic material.

Authors:  S M Tadavarthy; J H Moller; K Amplatz
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1975-11

4.  Iron-acrylic compound for steriotaxic aneurysm thrombosis.

Authors:  J F Alksne; R W Smith
Journal:  J Neurosurg       Date:  1977-08       Impact factor: 5.115

5.  Stereotaxic thrombosis of inaccessible intracranial aneurysms.

Authors:  R W Smith; J F Alksne
Journal:  J Neurosurg       Date:  1977-12       Impact factor: 5.115

6.  Preliminary report of a hollow-centered balloon for intravascular occlusion of intracranial aneurysms or arteriovenous fistulas. Technical note.

Authors:  M D Heifetz; G B Hieshima; C M Mehringer
Journal:  J Neurosurg       Date:  1980-08       Impact factor: 5.115

7.  Detachable balloon and calibrated-leak balloon techniques in the treatment of cerebral vascular lesions.

Authors:  G Debrun; P Lacour; J P Caron; M Hurth; J Comoy; Y Keravel
Journal:  J Neurosurg       Date:  1978-11       Impact factor: 5.115

  7 in total
  1 in total

1.  Electromagnetic field focusing (EFF) probe in aneurysm thrombosis. Preliminary report.

Authors:  A A Patil; W Yamanashi; J Valentine; D Hill; R E Woosley; O F Filip
Journal:  Acta Neurochir (Wien)       Date:  1986       Impact factor: 2.216

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.