Literature DB >> 6740771

Reliability of aspiration biopsy in thyroid nodes: study of 2190 operated patients.

M Radetić, Z Kralj, I Padovan.   

Abstract

The cytologic finding was negative in 1841 patients; accurate in 1763 (95.8%). Suspicious cytology proved malignant in 82 of 252 patients (32.5%). Positive cytology was accurate in 88 out of 97 cases (90.7%). In 1942 benign goiters, cytology was accurate in 90.8% of patients, false suspicious in 8.7% and false positive in 0.5%; the highest percentage of misdiagnosis was in adenomas (15.8%) and thyroiditis (19.0). In 248 malignant goiters, cytology was accurate in 35.5% of patients, suspicious in 33.1%, and false negative in 31.4%. False-negative cytology was found in 44% of follicular cancers, 22.2% of papillary and medullary, and 12.9% anaplastic. The most frequent false-negative cytologic diagnosis was the adenomatous goiter. The accuracy of cytology was statistically higher in papillary cancers than in follicular (77.8% vs 56.0%), in undifferentiated tumors than in differentiated (83.7% vs 65.0%), and in adenomatous nontoxic goiters than in adenomas, thyroiditis and toxic goiters (80.3% vs 42.7%), 20.1% and 13.4%). Positive preoperative fine needle aspiration biopsy cytology is a worthwhile and reliable finding; it fails in less than 10% of patients. Negative cytology, however, does not exclude malignancy in thyroid nodes; it is false negative in more than 30% of cancers.

Entities:  

Mesh:

Year:  1984        PMID: 6740771     DOI: 10.1177/030089168407000313

Source DB:  PubMed          Journal:  Tumori        ISSN: 0300-8916


  4 in total

1.  Prognostic factors and follow-up of patients with differentiated thyroid carcinoma with false negative or nondiagnostic FNAC before surgery. Comparison with a control group.

Authors:  Luis García-Pascual; Montserrat Balsells; Matteo Fabbi; Carlos Del Pozo; María-Teresa Valverde; Jaume Casalots; José-Manuel González-González; Enrique Veloso; Jordi Anglada-Barceló
Journal:  Endocrine       Date:  2011-05-04       Impact factor: 3.633

2.  Correlation of fine needle aspiration cytology with histopathology in the diagnosis of solitary thyroid nodule.

Authors:  Manoj Gupta; Savita Gupta; Ved Bhushan Gupta
Journal:  J Thyroid Res       Date:  2010-04-18

3.  Analysis of inconclusive fine-needle aspiration of thyroid follicular lesions.

Authors:  Nasir A Bakshi; Ibrahim Mansoor; Bruce A Jones
Journal:  Endocr Pathol       Date:  2003       Impact factor: 3.943

4.  Features and diagnostic accuracy of fine needle aspiration cytology of thyroid nodules: retrospective study from Oman.

Authors:  Rafie Alhassan; Noor Al Busaidi; Abdul Hakeem Al Rawahi; Hilal Al Musalhi; Ali Al Muqbali; Prakash Shanmugam; Fatma Ali Ramadhan
Journal:  Ann Saudi Med       Date:  2022-08-04       Impact factor: 1.707