Literature DB >> 6734564

Overview of a system for the computer-assisted operation of a small animal inhalation facility.

E W Van Stee, M P Moorman.   

Abstract

Automatic monitoring of the concentration of test gases and other environmental variables in small animal inhalation exposure chambers, coupled with computing capability and feedback control of the concentration of test gas, allows almost fully automatic operation of the chambers with a minimal amount of human intervention. Time-varying exposure profiles may be generated repeatedly with great accuracy, thus allowing a more realistic simulation of real-life exposures than is approached by operating chambers manually at ostensibly constant concentrations of test gases. Carefully conducted, pre-experimental calibration procedures are performed, and daily calibration checks allow statistical control of daily chamber operation and longer term quality control. At the conclusion of each experiment the investigator is supplied with records that document chamber conditions that have been monitored throughout the entire experiment, with estimates of the accuracy that was achieved in creating the specified exposure profile. A purpose of this report is to help to bridge the gap between the practicing inhalation toxicologist and the engineer in order to encourage their cooperation and mutual understanding of the technical problems involved in developing computer-assistance packages for inhalation facilities.

Entities:  

Mesh:

Year:  1984        PMID: 6734564      PMCID: PMC1568167          DOI: 10.1289/ehp.8454299

Source DB:  PubMed          Journal:  Environ Health Perspect        ISSN: 0091-6765            Impact factor:   9.031


  2 in total

1.  Animal inhalation exposure chambers.

Authors:  R G Hinners; J K Burkart; C L Punte
Journal:  Arch Environ Health       Date:  1968-02

2.  Calibration of a system for the computer-assisted operation of a small animal inhalation facility.

Authors:  E W Van Stee; M P Moorman
Journal:  Environ Health Perspect       Date:  1984-03       Impact factor: 9.031

  2 in total
  2 in total

1.  Development of a large-scale computer-controlled ozone inhalation exposure system for rodents.

Authors:  Gregory J Smith; Leon Walsh; Mark Higuchi; Samir N P Kelada
Journal:  Inhal Toxicol       Date:  2019-04-25       Impact factor: 2.724

2.  Calibration of a system for the computer-assisted operation of a small animal inhalation facility.

Authors:  E W Van Stee; M P Moorman
Journal:  Environ Health Perspect       Date:  1984-03       Impact factor: 9.031

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.