Literature DB >> 6731311

Atrioventricular valve anular diameter: two-dimensional echocardiographic-autopsy correlation.

H P Gutgesell, J T Bricker, E V Colvin, L A Latson, E P Hawkins.   

Abstract

To study the accuracy of 2-dimensional echocardiography (2-D echo) in estimating mitral and tricuspid anular diameter, 2-D echo estimates were compared with autopsy measurements of anular diameter in 21 children studied by echo within 30 days of death. The mitral anulus was measured from the left parasternal long axis view and the apical or subcostal 4-chamber image and the tricuspid anulus from the 4-chamber view. Comparable measurements were made from the autopsy specimen with calipers. The correlation coefficient for echocardiographic vs autopsy measurements was 0.79 (standard error of the estimate 2.8 mm) (mitral long axis r = 0.76, mitral 4-chamber r = 0.85, tricuspid 4-chamber r = 0.76). Echo measurements exceeded the corresponding autopsy measurements by an average of 17%; this was at least partially attributed to shrinkage of the specimen during fixation. Thus, 2-D echo may be used to provide a reasonable estimate of mitral and tricuspid anular diameter.

Entities:  

Mesh:

Year:  1984        PMID: 6731311     DOI: 10.1016/0002-9149(84)90596-4

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  6 in total

1.  Two-dimensional echocardiographic valve measurements in healthy children: gender-specific differences.

Authors:  M V Zilberman; P R Khoury; R T Kimball
Journal:  Pediatr Cardiol       Date:  2005 Jul-Aug       Impact factor: 1.655

2.  Cross-sectional echocardiographic measurements of right ventricular size and growth in patients with pulmonary atresia and intact ventricular septum.

Authors:  K Hanséus; G Björkhem; N R Lundström; S Laurin
Journal:  Pediatr Cardiol       Date:  1991-07       Impact factor: 1.655

3.  Relationship of Echocardiographic Z Scores Adjusted for Body Surface Area to Age, Sex, Race, and Ethnicity: The Pediatric Heart Network Normal Echocardiogram Database.

Authors:  Leo Lopez; Steven Colan; Mario Stylianou; Suzanne Granger; Felicia Trachtenberg; Peter Frommelt; Gail Pearson; Joseph Camarda; James Cnota; Meryl Cohen; Andreea Dragulescu; Michele Frommelt; Olukayode Garuba; Tiffanie Johnson; Wyman Lai; Joseph Mahgerefteh; Ricardo Pignatelli; Ashwin Prakash; Ritu Sachdeva; Brian Soriano; Jonathan Soslow; Christopher Spurney; Shubhika Srivastava; Carolyn Taylor; Poonam Thankavel; Mary van der Velde; LuAnn Minich
Journal:  Circ Cardiovasc Imaging       Date:  2017-11       Impact factor: 7.792

4.  Normal mitral and aortic valve areas assessed by three- and two-dimensional echocardiography in 168 children and young adults.

Authors:  T Poutanen; T Tikanoja; H Sairanen; E Jokinen
Journal:  Pediatr Cardiol       Date:  2006 Mar-Apr       Impact factor: 1.655

5.  Normal Reference Ranges for Cardiac Valve Annulus in Preterm Infants.

Authors:  Lulu Abushaban; Mariappa Thinakar Vel; Jebaraj Rathinasamy; Prem N Sharma
Journal:  Pediatr Cardiol       Date:  2015-09-01       Impact factor: 1.655

6.  Reference values for mitral and tricuspid annular dimensions using two-dimensional echocardiography.

Authors:  Girish Dwivedi; Ganadevan Mahadevan; Donie Jimenez; Michael Frenneaux; Richard P Steeds
Journal:  Echo Res Pract       Date:  2014-09-24
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.