This paper provides some details of a new insulin delivery system which includes a reservoir, a pump and a power pack. The reservoir holds 50 ml and is coupled to a precision peristaltic pump whose delivery can be set to any one of 128 different mean flow rates from 0 to 80 microliter/min (+/- 1.6% over 10 months) using the flow rate controller included in the battery power pack. The system weighs 525 g consuming 60 mW at the maximum pumping rate, proportionately less at lower rates. Ten pumps have undergone bench tests for 30 days. One has been subjected to an extended life test of 11 months while seven complete systems have been used on dogs to demonstrate their capability for precise longterm intravenous insulin therapy. With this system experimental diabetes has been reversed in 4 dogs for periods now extending beyond 6 months. This device now qualifies for long-term studies on hospitalized patients with diabetes mellitus.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 672822

Source DB:  PubMed          Journal:  Med Prog Technol        ISSN: 0047-6552


  6 in total

1.  Controlled release micropump for insulin administration.

Authors:  M V Sefton; H M Lusher; S R Firth; M U Waher
Journal:  Ann Biomed Eng       Date:  1979       Impact factor: 3.934

2.  Stabilized glucagon formulation for bihormonal pump use.

Authors:  Solomon S Steiner; Ming Li; Robert Hauser; Roderike Pohl
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

3.  An implantable artificial pancreas.

Authors:  W Schubert; P Baurschmidt; J Nagel; R Thull; M Schaldach
Journal:  Med Biol Eng Comput       Date:  1980-07       Impact factor: 2.602

4.  Assessment of an algorithm for the artificial B-cell using the normal insulin-glucose relationship in diabetic dogs and men.

Authors:  U Fischer; E Jutzi; H Bombor; E J Freyse; E Salzieder; G Albrecht; W Besch; W Bruns
Journal:  Diabetologia       Date:  1980       Impact factor: 10.122

5.  Blood glucose regulation using an open-loop insulin delivery system in pancreatectomized dogs given glucose infusions. I. Portal square waves.

Authors:  A M Albisser; C K Botz; B S Leibel
Journal:  Diabetologia       Date:  1979-02       Impact factor: 10.122

6.  Blood glucose regulation using closed- and open-loop insulin delivery systems. II. Peripheral primed square wave infusions.

Authors:  C K Botz; E B Marliss; A M Albisser
Journal:  Diabetologia       Date:  1979-07       Impact factor: 10.122

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.