Literature DB >> 6725683

Surface coil magnetic resonance imaging.

L Axel.   

Abstract

A surface coil is used as a receiver in a crossed-coil arrangement with a conventional circumferential transmitter coil in a magnetic resonance imaging system. The improved signal-to-noise ratio for objects close to the coil, compared with a conventional circumferential saddle-shaped receiver coil, permits higher resolution imaging of relatively superficial structures such as the orbit, neck, chest wall, and lumbar spine.

Mesh:

Year:  1984        PMID: 6725683     DOI: 10.1097/00004728-198406000-00002

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  9 in total

1.  NMR instrumentation and hardware available at present and in the future.

Authors:  E W McFarland; B R Rosen
Journal:  Cardiovasc Intervent Radiol       Date:  1986       Impact factor: 2.740

2.  Phase and sensitivity of receiver coils in magnetic resonance imaging.

Authors:  E R McVeigh; M J Bronskill; R M Henkelman
Journal:  Med Phys       Date:  1986 Nov-Dec       Impact factor: 4.071

3.  A Review of Non-1H RF Receive Arrays in Magnetic Resonance Imaging and Spectroscopy.

Authors:  Matthew Wilcox; Steven M Wright; Mary McDougall
Journal:  IEEE Open J Eng Med Biol       Date:  2020-10-13

4.  The misunderstood meander: Redesigning MRI meander-line surface coils to reduce noise, increase uniformity, and eliminate image artifacts.

Authors:  Gary Zabow; Stephen Dodd; Alan Koretsky
Journal:  J Magn Reson       Date:  2021-10-30       Impact factor: 2.734

5.  Magnetic resonance imaging in the diagnosis of spinal cord diseases.

Authors:  F Aichner; W Poewe; W Rogalsky; K Wallnöfer; J Willeit; F Gerstenbrand
Journal:  J Neurol Neurosurg Psychiatry       Date:  1985-12       Impact factor: 10.154

Review 6.  Recent Progress in the Preparation Technologies for Micro Metal Coils.

Authors:  Jianyong Lou; Haixia Ren; Xia Chao; Kesong Chen; Haodong Bai; Zhengyue Wang
Journal:  Micromachines (Basel)       Date:  2022-05-31       Impact factor: 3.523

7.  Correcting surface coil excitation inhomogeneities in single-shot SPEN MRI.

Authors:  Rita Schmidt; Mor Mishkovsky; Jean-Noel Hyacinthe; Nicolas Kunz; Rolf Gruetter; Arnaud Comment; Lucio Frydman
Journal:  J Magn Reson       Date:  2015-09-04       Impact factor: 2.229

8.  Applicability of deep learning-based reconstruction trained by brain and knee 3T MRI to lumbar 1.5T MRI.

Authors:  Nobuo Kashiwagi; Hisashi Tanaka; Yuichi Yamashita; Hiroto Takahashi; Yoshimori Kassai; Masahiro Fujiwara; Noriyuki Tomiyama
Journal:  Acta Radiol Open       Date:  2021-06-18

Review 9.  Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the art.

Authors:  Bernhard L Gerber; Subha V Raman; Krishna Nayak; Frederick H Epstein; Pedro Ferreira; Leon Axel; Dara L Kraitchman
Journal:  J Cardiovasc Magn Reson       Date:  2008-04-28       Impact factor: 5.364

  9 in total