| Literature DB >> 6725189 |
Abstract
A reverse phase liquid chromatographic method was developed for determining methocarbamol in injection and tablet dosage forms. The injections require dilution only; the tablets require a filtration step before introduction into the chromatograph. Response for methocarbamol was linear over the range 0-18 micrograms, using an ultraviolet detector at 274 nm. Recoveries by the author ranged from 96.1 to 101.9% for authentic injection formulations and 98.0 to 101.0% for authentic tablet formulations. A collaborative study of the method by 6 laboratories resulted in standard deviations of 1.70 and 2.22 for injection and tablet dosage forms, respectively. The method has been adopted official first action.Entities:
Mesh:
Substances:
Year: 1984 PMID: 6725189
Source DB: PubMed Journal: J Assoc Off Anal Chem ISSN: 0004-5756