Cancellous bone screws for repair of proximal growth plate fractures of the tibia in foals.

P C Wagner, R M DeBowes, B D Grant, A J Kaneps, B J Watrous.   

Abstract

Proximal growth plate fractures of the tibia in 4 foals were treated surgically. A medial approach was utilized in 3 cases and a lateral approach in the fourth. Bone screw fixation was achieved with cancellous screws and washers. In 3 cases, the screw shaft crossed the proximal tibial growth plate with no adverse effects. In all animals, there was rapid and cosmetic healing. At 8 to 18 months after surgery, all horses were sound at a walk, trot, and canter.

Entities:  

Mesh:

Year:  1984        PMID: 6725102

Source DB:  PubMed          Journal:  J Am Vet Med Assoc        ISSN: 0003-1488            Impact factor:   1.936


  1 in total

1.  Surgical management of a Salter-Harris type I proximal physeal fracture of the tibia in a foal: a case report.

Authors:  Ramin Mazaheri-Khameneh; Saeed Azizi; Farshid Davoodi; Mohammad Mahdi Gooran
Journal:  BMC Vet Res       Date:  2022-05-16       Impact factor: 2.792