Literature DB >> 67199

Two cases of giant intracerebral aneurysm simulating neoplasm on ct scan; one with coexistent chronic subdural hematoma.

J N Jones, H J Schwarz.   

Abstract

Two cases of giant intracerebral aneurysm are presented. Both exhibit increased absorption values in a circumferential configuration peripherally after the administration of contrast material. In addition, one case demonstrates a coexistent contralateral chronic subdural hematoma. No previous example of intracranial aneurysm exhibiting this configuration on computed tomography has been described in the literature. The operative, computed tomographic, radionuclide and angiographic findings are described and the differential diagnosis discussed.

Entities:  

Mesh:

Year:  1977        PMID: 67199     DOI: 10.1007/BF00312549

Source DB:  PubMed          Journal:  J Neurol        ISSN: 0340-5354            Impact factor:   4.849


  8 in total

1.  Computerized transverse tomography of vascular lesions of the brain. Part II: aneurysms.

Authors:  B D Pressman; G E Gilbert; D O Davis
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1975-06

2.  An extravascular component of contrast enhancement in cranial computed tomography. Part I. The tissue-blood ratio of contrast enhancement.

Authors:  M H Gado; M E Phelps; R E Coleman
Journal:  Radiology       Date:  1975-12       Impact factor: 11.105

3.  Computerized axial tomography of intracerebral and intraventricular hemorrhage.

Authors:  W R Scott; P F New; K R Davis; J A Schnur
Journal:  Radiology       Date:  1974-07       Impact factor: 11.105

4.  Computerized x-ray scanning of the brain.

Authors:  J Ambrose
Journal:  J Neurosurg       Date:  1974-06       Impact factor: 5.115

5.  Computer assisted tomography of the head. An early evaluation.

Authors:  H L Baker; J K Campbell; O W Houser; D F Reese; P F Sheedy; C B Holman
Journal:  Mayo Clin Proc       Date:  1974-01       Impact factor: 7.616

6.  Computerized tomography of the brain.

Authors:  D O Davis; B D Pressman
Journal:  Radiol Clin North Am       Date:  1974-08       Impact factor: 2.303

7.  Computerized axial tomography with the EMI scanner.

Authors:  P F New; W R Scott; J A Schnur; K R Davis; J M Taveras
Journal:  Radiology       Date:  1974-01       Impact factor: 11.105

8.  The EMI scanner. A brief review of the first 650 patients.

Authors:  R Paxton; J Ambrose
Journal:  Br J Radiol       Date:  1974-09       Impact factor: 3.039

  8 in total
  2 in total

Review 1.  Giant cerebral aneurysms.

Authors:  H W Pia; J Zierski
Journal:  Neurosurg Rev       Date:  1982       Impact factor: 3.042

2.  Extracranial-intracranial arterial bypass for giant aneurysms.

Authors:  K A Bushe; J Bockhorn
Journal:  Acta Neurochir (Wien)       Date:  1980       Impact factor: 2.216

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.