Literature DB >> 6718487

Noise and contrast detection in computed tomography images.

K Faulkner, B M Moores.   

Abstract

A discrete representation of the reconstruction process is used in an analysis of noise in computed tomography (CT) images. This model is consistent with the method of data collection in actual machines. An expression is derived which predicts the variance on the measured linear attenuation coefficient of a single pixel in an image. The dependence of the variance on various CT scanner design parameters such as pixel size, slice width, scan time, number of detectors, etc., is then described. The variation of noise with sampling area is theoretically explained. These predictions are in good agreement with a set of experimental measurements made on a range of CT scanners. The equivalent sampling aperture of the CT process is determined and the effect of the reconstruction filter on the variance of the linear attenuation coefficient is also noted, in particular, the choice and its consequences for reconstructed images and noise behaviour. The theory has been extended to include contrast detail behaviour, and these predictions compare favourably with experimental measurements. The theory predicts that image smoothing will have little effect on the contrast-detail detectability behaviour of reconstructed images.

Mesh:

Year:  1984        PMID: 6718487     DOI: 10.1088/0031-9155/29/4/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Image covariance and lesion detectability in direct fan-beam x-ray computed tomography.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  Phys Med Biol       Date:  2008-04-18       Impact factor: 3.609

2.  Image reconstruction from limited angle projections collected by multisource interior x-ray imaging systems.

Authors:  Baodong Liu; Ge Wang; Erik L Ritman; Guohua Cao; Jianping Lu; Otto Zhou; Li Zeng; Hengyong Yu
Journal:  Phys Med Biol       Date:  2011-09-09       Impact factor: 3.609

Review 3.  In vivo small-animal imaging using micro-CT and digital subtraction angiography.

Authors:  C T Badea; M Drangova; D W Holdsworth; G A Johnson
Journal:  Phys Med Biol       Date:  2008-08-29       Impact factor: 3.609

4.  Synchrotron radiation computed laminography for polymer composite failure studies.

Authors:  Feng Xu; Lukas Helfen; Andrew J Moffat; Gregory Johnson; Ian Sinclair; Tilo Baumbach
Journal:  J Synchrotron Radiat       Date:  2010-01-30       Impact factor: 2.616

5.  Visualization and Pathological Characteristics of Hepatic Alveolar Echinococcosis with Synchrotron-based X-ray Phase Sensitive Micro-tomography.

Authors:  Huiqiang Liu; Xuewen Ji; Li Sun; Tiqiao Xiao; Honglan Xie; Yanan Fu; Yuan Zhao; Wenya Liu; Xueliang Zhang; Renyong Lin
Journal:  Sci Rep       Date:  2016-11-29       Impact factor: 4.379

6.  Co-Clinical Imaging Resource Program (CIRP): Bridging the Translational Divide to Advance Precision Medicine.

Authors:  Kooresh I Shoghi; Cristian T Badea; Stephanie J Blocker; Thomas L Chenevert; Richard Laforest; Michael T Lewis; Gary D Luker; H Charles Manning; Daniel S Marcus; Yvonne M Mowery; Stephen Pickup; Ann Richmond; Brian D Ross; Anna E Vilgelm; Thomas E Yankeelov; Rong Zhou
Journal:  Tomography       Date:  2020-09
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.