Design, implementation and evaluation of a microcomputer-based portable arrhythmia monitor.

N V Thakor, J G Webster, W J Tompkins.   

Abstract

Entities:  

Mesh:

Year:  1984        PMID: 6717105     DOI: 10.1007/bf02446819

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


× No keyword cloud information.
  9 in total

1.  New method for heart studies.

Authors:  N J HOLTER
Journal:  Science       Date:  1961-10-20       Impact factor: 47.728

2.  Optimal QRS detector.

Authors:  N V Thakor; J G Webster; W J Tompkins
Journal:  Med Biol Eng Comput       Date:  1983-05       Impact factor: 2.602

3.  Arrhythmia detection program for an ambulatory ECG monitor.

Authors:  W C Mueller
Journal:  Biomed Sci Instrum       Date:  1978 Apr 17-18

4.  Reliable R-wave detection from ambulatory subjects.

Authors:  N V Thakor
Journal:  Biomed Sci Instrum       Date:  1978 Apr 17-18

5.  A portable microcomputer-based system for biomedical applications.

Authors:  W J Tompkins
Journal:  Biomed Sci Instrum       Date:  1978 Apr 17-18

6.  An intelligent monitor for ambulatory ECGS.

Authors:  J G Webster
Journal:  Biomed Sci Instrum       Date:  1978 Apr 17-18

7.  A battery-powered digital modem for telephone transmission of ECG data.

Authors:  N V Thakor; J G Webster; W J Tompkins
Journal:  IEEE Trans Biomed Eng       Date:  1982-05       Impact factor: 4.538

8.  Low-power electrocardiographic data-acquisition module for microprocessor systems.

Authors:  M Fostik; T Conway; R Dwinell; J Singer
Journal:  Med Biol Eng Comput       Date:  1980-01       Impact factor: 2.602

9.  Design and evaluation of QRS and noise detectors for ambulatory e.c.g. monitors.

Authors:  N V Thakor; J G Webster
Journal:  Med Biol Eng Comput       Date:  1982-11       Impact factor: 2.602

  9 in total
  4 in total

1.  Ambulatory monitoring device using the fan method as data-compression algorithm.

Authors:  M Giallorenzo; J Cohen; F Mora; G Passariello; L O Lara
Journal:  Med Biol Eng Comput       Date:  1988-07       Impact factor: 2.602

2.  Electrode studies for the long-term ambulatory ECG.

Authors:  N V Thakor; J G Webster
Journal:  Med Biol Eng Comput       Date:  1985-03       Impact factor: 2.602

3.  Optimal QRS detector.

Authors:  N V Thakor; J G Webster; W J Tompkins
Journal:  Med Biol Eng Comput       Date:  1983-05       Impact factor: 2.602

4.  Electrocardiographic ambulatory monitoring with a real-time analysis system.

Authors:  A Ferraioli; G Scotto di Quaquaro; G Murino; C Romaldo; G Di Mauro
Journal:  J Clin Monit       Date:  1990-10
  4 in total