Literature DB >> 6716199

Symmetry and constancy in the perception of negative and positive luminance contrast.

D A Burkhardt, J Gottesman, D Kersten, G E Legge.   

Abstract

The perception of suprathreshold luminance contrast was investigated by forced-choice psychophysical procedures that were designed to define contrast equivalence relations. Observers compared the perceived contrast of rectangular bars that were presented for 500 msec at 3.9 deg on opposite sides of the fovea. The results show a nearly symmetrical relation between the perception of negative and positive contrast that is largely invariant over four decades of background luminance. Thus, for any fixed background luminance, equal absolute contrasts evoke approximately equal perceived contrasts. Symmetry also held with variations in the width, the eccentricity, and the focus of the bars. Symmetry was investigated further by determining equivalent contrast relations for negative contrasts as a function of background luminance and by contrast scaling. These results show evidence for nearly perfect contrast constancy for targets of low to moderate contrast and departures form constancy for high-contrast targets. These new findings on negative contrast, symmetry, and contrast constancy are discussed in relation to underlying mechanisms for contrast perception and classic experiments on brightness and lightness constancy.

Entities:  

Mesh:

Year:  1984        PMID: 6716199     DOI: 10.1364/josaa.1.000309

Source DB:  PubMed          Journal:  J Opt Soc Am A        ISSN: 0740-3232            Impact factor:   2.129


  5 in total

1.  Cue combination in the motion correspondence problem.

Authors:  P B Hibbard; M F Bradshaw; R A Eagle
Journal:  Proc Biol Sci       Date:  2000-07-07       Impact factor: 5.349

2.  Directional asymmetries and age effects in human self-motion perception.

Authors:  Rachel E Roditi; Benjamin T Crane
Journal:  J Assoc Res Otolaryngol       Date:  2012-03-09

3.  Spatial and temporal properties of cone signals in alert macaque primary visual cortex.

Authors:  Bevil R Conway; Margaret S Livingstone
Journal:  J Neurosci       Date:  2006-10-18       Impact factor: 6.167

4.  New Contrast Metric for Realistic Display Performance Measure.

Authors:  Alex D Hwang; Eli Peli
Journal:  Dig Tech Pap       Date:  2016-05-25

5.  First-order visual interneurons distribute distinct contrast and luminance information across ON and OFF pathways to achieve stable behavior.

Authors:  Madhura D Ketkar; Burak Gür; Sebastian Molina-Obando; Maria Ioannidou; Carlotta Martelli; Marion Silies
Journal:  Elife       Date:  2022-03-09       Impact factor: 8.713

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.