Literature DB >> 6715386

Compressibility and constitutive equation of arterial wall in radial compression experiments.

C J Chuong, Y C Fung.   

Abstract

A large number of papers treat the tensile properties of arterial wall, but few treat compressive properties. Almost everybody assumes incompressibility; few have measured the vessel wall fluid extrusion due to compressive loading. In this work, uniaxial compressive force is applied directly on rabbit thoracic artery in the radial direction to study its constitutive equation under compressive stresses. The resulting stress-strain curves show that the wall material becomes increasingly stiffer at larger compressive strain, quite similar to the behavior in tension. A pseudo-strain energy function of the exponential type which has been applied successfully on the tension side is used to identify the material constants on the compression side. The material constants are identified in two ways: with and without the assumption of incompressibility. To determine the compressibility of the wall, the fluid extrusion accompanying this type of loading is measured, and is found to be in the range of 0.50-1.26% of the undeformed tissue volume per 10 kPa compressive stress loading in the radial direction. At compressive stresses higher than 30 kPa, the percentage of fluid extrusion per unit compressive stress decreases. At this degree of fluid extrusion the tissue is only slightly compressible (or nearly incompressible). However, the use of incompressibility assumption in the stress-strain relationship results in a set of material constants which is very different from that derived without that assumption.

Entities:  

Mesh:

Year:  1984        PMID: 6715386     DOI: 10.1016/0021-9290(84)90077-0

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  18 in total

1.  Effects of Geometric Variations on the Buckling of Arteries.

Authors:  Parag Datir; Avione Y Lee; Shawn D Lamm; Hai-Chao Han
Journal:  Int J Appl Mech       Date:  2011-10-05       Impact factor: 3.224

Review 2.  What are the residual stresses doing in our blood vessels?

Authors:  Y C Fung
Journal:  Ann Biomed Eng       Date:  1991       Impact factor: 3.934

3.  Quasi-linear viscoelastic modeling of arterial wall for surgical simulation.

Authors:  Tao Yang; Chee Kong Chui; Rui Qi Yu; Jing Qin; Stephen K Y Chang
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-04-13       Impact factor: 2.924

4.  Behaviour of two typical stents towards a new stent evolution.

Authors:  M Simão; J M Ferreira; J Mora-Rodriguez; J Fragata; H M Ramos
Journal:  Med Biol Eng Comput       Date:  2016-09-26       Impact factor: 2.602

5.  Modeling water flow through arterial tissue.

Authors:  M Klanchar; J M Tarbell
Journal:  Bull Math Biol       Date:  1987       Impact factor: 1.758

6.  Constitutive modeling of coronary arterial media--comparison of three model classes.

Authors:  Yaniv Hollander; David Durban; Xiao Lu; Ghassan S Kassab; Yoram Lanir
Journal:  J Biomech Eng       Date:  2011-06       Impact factor: 2.097

7.  Determination of the mechanical properties of the different layers of blood vessels in vivo.

Authors:  Y C Fung; S Q Liu
Journal:  Proc Natl Acad Sci U S A       Date:  1995-03-14       Impact factor: 11.205

8.  Finite-element analysis of balloon angioplasty.

Authors:  S Oh; M Kleinberger; J H McElhaney
Journal:  Med Biol Eng Comput       Date:  1994-07       Impact factor: 2.602

9.  Linked opening angle and histological and mechanical aspects of the proximal pulmonary arteries of healthy and pulmonary hypertensive rats and calves.

Authors:  Lian Tian; Steven R Lammers; Philip H Kao; Mark Reusser; Kurt R Stenmark; Kendall S Hunter; H Jerry Qi; Robin Shandas
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-08-19       Impact factor: 4.733

10.  Sequential multimodal microscopic imaging and biaxial mechanical testing of living multicomponent tissue constructs.

Authors:  Yuqiang Bai; Po-Feng Lee; Jay D Humphrey; Alvin T Yeh
Journal:  Ann Biomed Eng       Date:  2014-05-10       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.