Literature DB >> 6714249

Study of ECG-gated thallium-201 myocardial scintigraphy: is imaging time a limiting factor?

I Garty, A Kardontchik.   

Abstract

Twenty patients underwent gated synchronized 201Tl myocardial scanning (TMS). Twelve also performed a rest blood pool multigated acquisition ( MUGA ) study. A 'static' image was obtained by adding all the gated frames of the study. In this way we found the conventional static study quite unnecessary. Comparing the gated TMS to the static one revealed significantly improved resolution in the gated images and additional information concerning wall motion and myocardial thickness. Close agreement was found with results of MUGA studies of the same patients. By the addition of diastolic frames the imaging time needed to obtain improved image quality was found to be not more than 10 min per view. The exclusion of imaging time as a limiting factor for gated TMS is stressed.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6714249     DOI: 10.1007/bf00251466

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  11 in total

1.  Thallium-201 for myocardial imaging. Relation of thallium-201 to regional myocardial perfusion.

Authors:  H W Strauss; K Harrison; J K Langan; E Lebowitz; B Pitt
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

Review 2.  Thallium-201 myocardial scintigraphy: an overview.

Authors:  M S Verani
Journal:  Clin Nucl Med       Date:  1983-06       Impact factor: 7.794

3.  Simultaneous detection of myocardial perfusion and wall motion abnormalities by cinematic 201Tl imaging.

Authors:  P O Alderson; H N Wagner; J J Gomez-Moeiras; T G Rehn; L C Becker; K H Douglas; H F Manspeaker; G R Schindledecker
Journal:  Radiology       Date:  1978-05       Impact factor: 11.105

4.  Thallium-201 myocardial imaging: an interinstitutional study of observer variability.

Authors:  G B Trobaugh; F J Wackers; E B Sokole; T A DeRouen; J L Ritchie; G W Hamilton
Journal:  J Nucl Med       Date:  1978-04       Impact factor: 10.057

Review 5.  Thallium redistribution: mechanisms and clinical utility.

Authors:  G M Pohost; N M Alpert; J S Ingwall; H W Strauss
Journal:  Semin Nucl Med       Date:  1980-01       Impact factor: 4.446

6.  Thallium-201 myocardial imaging: characterization of the ECG-synchronized images.

Authors:  G W Hamilton; K A Narahara; G B Trobaugh; J L Ritchie; D L Williams
Journal:  J Nucl Med       Date:  1978-10       Impact factor: 10.057

7.  Sensitivity and specificity of thallium-201 perfusion scintigrams under exercise in the diagnosis of coronary artery disease.

Authors:  M S Verani; M L Marcus; M A Razzak; J C Ehrhardt
Journal:  J Nucl Med       Date:  1978-07       Impact factor: 10.057

8.  Thallium-201 myocardial scintigraphy in acute myocardial infarction and ischemia.

Authors:  F J Wackers
Journal:  Semin Nucl Med       Date:  1980-04       Impact factor: 4.446

9.  ECG gating of thallium-201 myocardial images: effect on detection of ischemic heart disease.

Authors:  J H McKillop; H D Fawcett; J E Baumert; I R McDougall; R F DeBusk; D C Harrison; M L Goris
Journal:  J Nucl Med       Date:  1981-03       Impact factor: 10.057

Review 10.  A consideration of factors affecting the diagnostic accuracy of thallium-201 myocarial perfusion scintigraphy in detecting coronary artery disease.

Authors:  E H Botvinick; R F Dunn; R S Hattner; B M Massie
Journal:  Semin Nucl Med       Date:  1980-04       Impact factor: 4.446

View more
  4 in total

1.  Quantitative analysis of myocardial ischaemia on end-diastolic thallium 201 perfusion images.

Authors:  G A Hurwitz; M E Schwab; A C MacDonald; A A Driedger
Journal:  Eur J Nucl Med       Date:  1990

2.  Comparison of technetium-99m sestamibi left ventricular wall motion and perfusion studies with thallium-201 perfusion imaging: in search of the combination of variables with the highest accuracy in predicting coronary artery disease.

Authors:  J F Verzijlbergen; A H Zwinderman; C A Ascoop; E E van der Wall; M G Niemeyer; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1996-05

3.  Evaluation of 3 dimensional space and time filtering on ECG gated 201Tl myocardial images.

Authors:  M H Bourguignon; H Valette; D Le Guludec; E K Pauwels; P Merlet; C Raynaud; A Syrota
Journal:  Eur J Nucl Med       Date:  1987

Review 4.  ECG gated thallium 201 myocardial images: value in detecting multivessel disease in patients on anti anginal therapy 1-3 months after myocardial infarction.

Authors:  H Valette; M H Bourguignon; D Le Guludec; P Merlet; P J Dove; J P Kiger; M Slama; G Motté; C Raynaud; A Syrota
Journal:  Eur J Nucl Med       Date:  1988
  4 in total