Literature DB >> 671254

Spectrophotofluorometric analysis of 3',4',7-tris[O-(beta-hydroxyethyl)]rutoside in urine.

H S Tan, P J Mowery, W A Ritschel, C Neu.   

Abstract

A sensitive procedure was developed for 3',4',7-tris[O(beta-hydroxyethyl)]rutoside (I) in urine. The method is based on the fluoresence behavior of the I-aluminum complex in absolute methanol. This complex has activation and emission wavelengths of 420 and 480 nm, respectively. Optimum conditions for the reaction were investigated. The fluorescence was linear (r = 0.998) in the range of 0.1-4.0 microgram of I/ml. At concentrations below 0.1 microgram/ml, a shift in the emission wavelength was observed. Replicate studies (n = 9) of spiked urine samples, each containing 0.4 microgram of I/ml, showed good precision with a relative standard deviation of 0.009. Overall percent recovery (+/- SEM) from five urine samples was 99.5 +/- 1.34%. Following a single 500-mg po dose of I to individuals, only traces of I were found in the urine. However, beta-glucuronidase treatment of urine resulted in a total cumulative urine excretion of 26.53 mg of I after 78.6 hr.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 671254     DOI: 10.1002/jps.2600670830

Source DB:  PubMed          Journal:  J Pharm Sci        ISSN: 0022-3549            Impact factor:   3.534


  1 in total

1.  O-(β-hydroxyethyl)rutosides determination by micellar flow injection (FI)-spectrofluorimetry.

Authors:  Cecilia Mariana Peralta; Liliana Patricia Fernández
Journal:  J Pharm Anal       Date:  2014-07-15