Literature DB >> 6708491

A general-purpose microprocessor system for medical instrumentation and electrical stimulation.

H G Goovaerts, C van Veen, M A Meekes.   

Abstract

The article describes the design of a user-defined multipurpose system based on the Zilog Z-80, 8-bit microprocessor. The basic concept comprises a mainframe with a keyboard/display interface for communication between user and system. Different types of instrumentation equipment can be obtained using the same mainframe; only the contents of the program memory have to be changed. Up to seven programmable input/output boards can be installed. Some special-purpose boards are constructed to improve the versatility of the system. The major advantage of the presented system is that it can be applied at any time in the laboratory in an experiment or in the hospital for diagnostic or therapeutic purposes, without the engagement of existing computer memory.

Mesh:

Year:  1984        PMID: 6708491     DOI: 10.1016/0141-5425(84)90049-9

Source DB:  PubMed          Journal:  J Biomed Eng        ISSN: 0141-5425


  8 in total

1.  Are eye movement evoked potentials different from pattern reversal evoked potentials?

Authors:  F C Riemslag; G L van der Heijde; M M van Dongen
Journal:  Doc Ophthalmol       Date:  1987-08       Impact factor: 2.379

2.  Isolated microelectrodes amplifier for measurements on papillary muscle subject to a rapid temperature step.

Authors:  H G Goovaerts; J W Metselaar
Journal:  Med Biol Eng Comput       Date:  1987-05       Impact factor: 2.602

3.  Computerised eye-movement processor for clinical applications: basic considerations and design.

Authors:  J P Reulen; R van Heuningen; G Tiesinga; J E Bos
Journal:  Med Biol Eng Comput       Date:  1986-03       Impact factor: 2.602

4.  Tracheal sound detector.

Authors:  J P Heemels; H H Ros; P Sipkema; F de Vries
Journal:  Med Biol Eng Comput       Date:  1986-03       Impact factor: 2.602

5.  Microprocessor-based system for measurement of electrical impedances during haemodialysis and in postoperative care.

Authors:  H G Goovaerts; F R de Vries; J H Meijer; P M de Vries; A J Donker; H Schneider
Journal:  Med Biol Eng Comput       Date:  1988-01       Impact factor: 2.602

6.  High-frequency power source for application of temperature steps in papillary tissue.

Authors:  H G Goovaerts; J W Metselaar
Journal:  Med Biol Eng Comput       Date:  1985-09       Impact factor: 2.602

7.  Method for the measurement of susceptibility to decubitus ulcer formation.

Authors:  J H Meijer; G L Schut; M W Ribbe; H G Goovaerts; R Nieuwenhuys; J P Reulen; H Schneider
Journal:  Med Biol Eng Comput       Date:  1989-09       Impact factor: 2.602

8.  Oculomotor control in Gilles de la Tourette syndrome.

Authors:  E L Bollen; R A Roos; A P Cohen; R B Minderaa; J P Reulen; B J Van de Wetering; T C Van Woerkom; O J Buruma
Journal:  J Neurol Neurosurg Psychiatry       Date:  1988-08       Impact factor: 10.154

  8 in total