Literature DB >> 6707973

Geometric accommodation between the dimensions of erythrocytes and the calibre of heart and muscle capillaries in the rat.

P B Canham, R F Potter, D Woo.   

Abstract

The finer and more closely arrayed the capillaries are, the more efficiently oxygen will be transported to tissue because the same blood volume has greater contact area with the tissue and the diffusion distance for the oxygen is minimized. If these principles are actually governing microvascular structure, then the finest capillaries will be the narrowest channels which circulating erythrocytes can transit. Ascertaining the existence of this geometric limit requires quantitative data of demonstrated reliability on erythrocyte geometry and on capillary diameters. The study was done on Wistar rats. Constant flow perfusion of skeletal and cardiac muscle by a modified Batson's compound for anatomical casting made available rigid three-dimensional replicas of the microvasculature which shrank less than 1% when the tissue was digested with potassium hydroxide. Measurements of individual capillaries were made on high contrast scanning electron micrographs of the casts. Measurements on individual rat erythrocytes were done on photomicrographs of cells on edge. Reliability of these data was tested in three ways. First, repeatability of the tracing of the cell outline was tested by processing a duplicate set of photomicrographs. Secondly, correlations of the various parameters were found. Thirdly, results from other techniques of measuring erythrocytes were examined for areas of agreement and also for causes of possible error for areas in dispute. Because of known variability in erythrocyte sizes and shapes between species and between individuals within a species, we compared the data on erythrocyte geometry and capillary diameters for samples taken from the same individual rat. The data revealed a very positive indication that the lowest range of capillary diameters were at the limits of deformation of the circulating erythrocytes. Ninety-five per cent of the erythrocytes sampled could pass through a channel 2.9 micron in diameter. A small number of the capillaries measured were narrower than this limit. The data on erythrocytes and capillaries were compared for six rats. The limiting diameter for passage of erythrocytes was remarkably uniform for all six animals.

Entities:  

Mesh:

Year:  1984        PMID: 6707973      PMCID: PMC1199472          DOI: 10.1113/jphysiol.1984.sp015091

Source DB:  PubMed          Journal:  J Physiol        ISSN: 0022-3751            Impact factor:   5.182


  11 in total

1.  Capillary diameter in rat heart in situ: relation to erythrocyte deformability, O2 transport, and transmural O2 gradients.

Authors:  L Henquell; P L LaCelle; C R Honig
Journal:  Microvasc Res       Date:  1976-11       Impact factor: 3.514

2.  Microvasculature of the dog left ventricular myocardium.

Authors:  J B Bassingthwaighte; T Yipintsoi; R B Harvey
Journal:  Microvasc Res       Date:  1974-03       Impact factor: 3.514

3.  An improved plastic mixture for corrosion casting of the gastrointestinal microvascular system.

Authors:  W Nopanitaya; J G Aghajanian; L D Gray
Journal:  Scan Electron Microsc       Date:  1979

4.  Improved measurements of the erythrocyte geometry.

Authors:  E Evans; Y C Fung
Journal:  Microvasc Res       Date:  1972-10       Impact factor: 3.514

5.  Geometric properties of individual red blood cell discocyte-spherocyte transformations.

Authors:  E A Evans; P F Leblond
Journal:  Biorheology       Date:  1973-09       Impact factor: 1.875

6.  Distribution of size and shape in populations of normal human red cells.

Authors:  P B Canham; A C Burton
Journal:  Circ Res       Date:  1968-03       Impact factor: 17.367

7.  High-resolution data on the geometry of red blood cells.

Authors:  Y C Fung; W C Tsang; P Patitucci
Journal:  Biorheology       Date:  1981       Impact factor: 1.875

8.  Quantitative reconstruction and superresolution of red-blood-cell image holograms.

Authors:  E A Evans
Journal:  J Opt Soc Am       Date:  1971-08

9.  Induced rouleaux formation in interspecies populations of red cells.

Authors:  L Sewchand; P B Canham
Journal:  Can J Physiol Pharmacol       Date:  1976-08       Impact factor: 2.273

10.  Capillary diameter and geometry in cardiac and skeletal muscle studied by means of corrosion casts.

Authors:  R F Potter; A C Groom
Journal:  Microvasc Res       Date:  1983-01       Impact factor: 3.514

View more
  4 in total

1.  Investigation of artifacts in retinal and choroidal OCT angiography with a contrast agent.

Authors:  Marcel T Bernucci; Conrad W Merkle; Vivek J Srinivasan
Journal:  Biomed Opt Express       Date:  2018-02-06       Impact factor: 3.732

2.  Intra-articular versus systemic vancomycin for the treatment of periprosthetic joint infection after debridement and spacer implantation in a rat model.

Authors:  Jian Wei; Kai Tong; Hui Wang; Yinxian Wen; Liaobin Chen
Journal:  Bone Joint Res       Date:  2022-06       Impact factor: 4.410

3.  Myocardial capillaries: increase in number by splitting of existing vessels.

Authors:  J P van Groningen; A C Wenink; L H Testers
Journal:  Anat Embryol (Berl)       Date:  1991

4.  Hyperinsulinemia does not cause de novo capillary recruitment in rat skeletal muscle.

Authors:  Thorbjorn Akerstrom; Daniel Goldman; Franciska Nilsson; Stephanie L Milkovich; Graham M Fraser; Christian Lehn Brand; Ylva Hellsten; Christopher G Ellis
Journal:  Microcirculation       Date:  2019-10-12       Impact factor: 2.628

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.