Study of bolus geometry after intravenous contrast medium injection: dynamic and quantitative measurements (Chronogram) using an X-ray CT device.

U J Reiser.   

Abstract

An X-ray computed tomographic (CT) scanner was used to measure and image transmission profiles of a single 8 mm thick object slice digitally with a high temporal (up to 20 ms), spatial (1.1 mm), and density (0.5%) resolution. This special digital radiography imaging mode is called a Chronogram. It produces a time-history of measured attenuation values but not a normal anatomical image. After intravenous bolus injection of contrast medium, bolus shape as a function of time and bolus passage times can be imaged. Absolute iodine concentrations in blood vessels and soft tissue can be evaluated at any time in all body regions. The Chronogram has the potential to quantify physiological parameters such as enhancement, passage times, and relative blood flow through pairs of arteries or symmetrically arranged organs and to measure absolute iodine concentrations. As a disadvantage, patient motion can prevent quantitative evaluation. This drawback can, however, be turned into an advantage in that all kinds of motion can be measured, for example, movement and pulsation of the heart.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6707275

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  4 in total

1.  Simultaneous measurement of regional cerebral blood flow by perfusion CT and stable xenon CT: a validation study.

Authors:  M Wintermark; J P Thiran; P Maeder; P Schnyder; R Meuli
Journal:  AJNR Am J Neuroradiol       Date:  2001-05       Impact factor: 3.825

2.  Estimation of regional gas and tissue volumes of the lung in supine man using computed tomography.

Authors:  D M Denison; M D Morgan; A B Millar
Journal:  Thorax       Date:  1986-08       Impact factor: 9.139

3.  Use of cardiac output to improve measurement of input function in quantitative dynamic contrast-enhanced MRI.

Authors:  Jeff L Zhang; Henry Rusinek; Louisa Bokacheva; Qun Chen; Pippa Storey; Vivian S Lee
Journal:  J Magn Reson Imaging       Date:  2009-09       Impact factor: 4.813

4.  Intraoperative fluorescence perfusion assessment should be corrected by a measured subject-specific arterial input function.

Authors:  Jonathan T Elliott; Rocco R Addante; Gerard-Paul Slobegean; Shudong Jiang; Eric R Henderson; Brian W Pogue; Ida Leah Gitajn
Journal:  J Biomed Opt       Date:  2020-06       Impact factor: 3.170

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.