Literature DB >> 6706783

Laser-Doppler measurement of skin blood flow: comparison with plethysmography.

J M Johnson, W F Taylor, A P Shepherd, M K Park.   

Abstract

We compared laser-Doppler velocimetry with plethysmographically determined changes in skin blood flow (SkBF) in five studies on four men. Increments in SkBF were induced by raising whole-body skin temperature to 39 degrees C for 50-70 min. We found laser-Doppler blood flow (LDF) to correlate well with total forearm blood flow (FBF) within each study (r = 0.94-0.98), but the relationship varied among studies. Thus the slopes for the LDF vs. FBF relationship varied from 40 to 122 mV X ml-1 X 100 ml X min. The value for LDF at zero FBF, extrapolated from the regression relationships, ranged from 246 to 599 mV above the value for LDF set with the probe on a stationary object. The value for LDF when blood flow to the arm was mechanically occluded ranged from 110 to 230 mV. In a second series, we measured the LDF values from six sites on forearms of each of four normothermic men. There was marked regional variation, with 1.8- to 5.7-fold ranges in LDF within a given subject. Values for LDF during occlusion of the forearm were more consistent within and between subjects. Thus LDF appears to provide a good indicator of the response pattern of SkBF from the region of illuminated skin. However, variability in the relationship to total SkBF (probably arising from variation in the number of perfused capillaries in the small volume of tissue) and uncertainties in the value of LDF at zero SkBF make quantitative use difficult.

Entities:  

Mesh:

Year:  1984        PMID: 6706783     DOI: 10.1152/jappl.1984.56.3.798

Source DB:  PubMed          Journal:  J Appl Physiol Respir Environ Exerc Physiol        ISSN: 0161-7567


  59 in total

Review 1.  Finger cold-induced vasodilation: a review.

Authors:  H A M Daanen
Journal:  Eur J Appl Physiol       Date:  2003-04-24       Impact factor: 3.078

2.  Effect of heat stress on muscle blood flow during dynamic handgrip exercise.

Authors:  J Smolander; V Louhevaara
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1992

3.  Skin vascular response in the hand during sinusoidal exercise in physically trained subjects.

Authors:  Fumio Yamazaki; Ryoko Sone
Journal:  Eur J Appl Physiol       Date:  2003-07-09       Impact factor: 3.078

4.  Measurement of the skin microcirculation through intact bandages using laser Doppler flowmetry.

Authors:  J M Melhuish; L Krishnamoorthy; T Bethaves; M Clark; R J Williams; K G Harding
Journal:  Med Biol Eng Comput       Date:  2004-03       Impact factor: 2.602

5.  Laser Doppler flowmetry in evaluation of cutaneous wound blood flow using various suturing techniques.

Authors:  G C Zografos; K Martis; D L Morris
Journal:  Ann Surg       Date:  1992-03       Impact factor: 12.969

6.  Methodological assessment of skin and limb blood flows in the human forearm during thermal and baroreceptor provocations.

Authors:  R Matthew Brothers; Jonathan E Wingo; Kimberly A Hubing; Craig G Crandall
Journal:  J Appl Physiol (1985)       Date:  2010-07-15

Review 7.  Local thermal control of the human cutaneous circulation.

Authors:  John M Johnson; Dean L Kellogg
Journal:  J Appl Physiol (1985)       Date:  2010-06-03

Review 8.  Thermal provocation to evaluate microvascular reactivity in human skin.

Authors:  Christopher T Minson
Journal:  J Appl Physiol (1985)       Date:  2010-05-27

9.  Effects of posture, hypotension and locally applied vasoconstriction on the middle ear microcirculation in anaesthetized humans.

Authors:  C S Degoute; C Dubreuil; M J Ray; J Guitton; M Manchon; V Banssillon; J L Saumet
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1994

10.  Magnesium sulphate only slightly reduces the shivering threshold in humans.

Authors:  A Wadhwa; P Sengupta; J Durrani; O Akça; R Lenhardt; D I Sessler; A G Doufas
Journal:  Br J Anaesth       Date:  2005-03-04       Impact factor: 9.166

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.