Literature DB >> 6705812

Quantitative evaluation of tricuspid regurgitation by digital simulation of cardiac time-activity curves.

M Hunault, N Tamaki, K Minato, T Mukai, K Torizuka, Y Konishi, M Kuwahara, Y Ishii.   

Abstract

To estimate tricuspid regurgitation (TR) quantitatively, a curve fitting method by computer has been employed. Transport in the right cardiac chambers after intravenous bolus injection of macro-aggregated albumin labeled with technetium 99m (99mTc-MAA) was recorded in anterior view by a gammacamera system. Disturbance of the dilution curves from the left heart can be avoided by using 99mTc-MAA injection. To know the radioisotope activity during the transport, time-activity curves are recorded for the superior vena cava, right atrium, and right ventricle. Parametric differential equations, obtained from compartmental analysis, interpret these curves mathematically. The rate of regurgitation is determined by comparison, using an iterative process, between the original and simulated curves. The whole process is performed automatically by computer. The calculated regurgitation value correlated well with the value from the analog simulation. The method clearly separated those with TR from those without TR. This digital simulation for estimating parameters using a compartmental model is a feasible tool in detecting and quantifying TR.

Entities:  

Mesh:

Year:  1984        PMID: 6705812     DOI: 10.1007/bf00254439

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  5 in total

1.  Left ventricle as a mixing chamber.

Authors:  H IRISAWA; M F WILSON; R F RUSHMER
Journal:  Circ Res       Date:  1960-01       Impact factor: 17.367

2.  Quantitative estimation of aortic regurgitation by analog computer analysis of radiocardiogram.

Authors:  S Motoara; M Saito; A Hirakawa; K Ogino; M Takayasu
Journal:  Jpn Circ J       Date:  1974-03

3.  Indicator mixing in the left heart and reexamination of mean circulation time.

Authors:  J Boyle
Journal:  J Appl Physiol       Date:  1974-10       Impact factor: 3.531

4.  Measurement of heart chamber volumes by analysis of dilution curves simultaneously recorded by scintillation camera.

Authors:  Y Ishii; W J MacIntyre
Journal:  Circulation       Date:  1971-07       Impact factor: 29.690

5.  Assessment of severity of tricuspid regurgitation by analog computer analysis of dilution curves recorded by scintillation camera.

Authors:  Y Konishi; N Tatsuta; Y Hikasa; N Tamaki; Y Ishii; K Torizuka
Journal:  Jpn Circ J       Date:  1982-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.