Literature DB >> 6703348

Maternal and neonatal effects of epidural morphine for labor and delivery.

S C Hughes, M A Rosen, S M Shnider, T K Abboud, S J Stefani, M Norton.   

Abstract

To determine the efficacy of epidural morphine during labor and delivery, 40 healthy parturients who requested epidural analgesia were randomly given either a single injection of morphine sulfate (2 mg, n = 9; 5 mg, n = 10; or 7.5 mg, n = 11) or 0.5% bupivacaine (n = 10). Bupivacaine provided excellent analgesia in all patients. Morphine (2 or 5 mg) did not produce adequate analgesia and needed to be supplemented by local anesthesia. Morphine (7.5 mg) gave satisfactory analgesia in 7 of 11 patients until the end of the first stage of labor, and, in an additional patient, for almost 13 hr, at which time cephalopelvic disproportion was diagnosed. In all patients given epidural morphine, local anesthesia was needed for the second stage of labor if instrumentation or episiotomy was required. The only side effect was pruritus, which occurred in three patients. Epidural morphine did not produce neonatal depression, as evidenced by Apgar scores and neurologic and adaptive capacity scores. We conclude that 7.5 mg of epidural morphine can give satisfactory pain relief during labor but not delivery, and that 2 or 5 mg of morphine is ineffective. Although 0.5% bupivacaine provided better anesthesia, epidural morphine might prove useful for selected patients.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6703348

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  5 in total

1.  Clinical experience of epidural fentanyl for labor pain.

Authors:  K Murakawa; T K Abboud; T Yanagi; F Sarkis; A Afrasiabi; A Sheikh-ol-Eslam; J Raya; M L Yonekura
Journal:  J Anesth       Date:  1987-03-01       Impact factor: 2.078

2.  Continuous epidural infusion of ketamine during labour.

Authors:  I Schneider; M Diltoer
Journal:  Can J Anaesth       Date:  1987-11       Impact factor: 5.063

Review 3.  Side effects of intrathecal and epidural opioids.

Authors:  M A Chaney
Journal:  Can J Anaesth       Date:  1995-10       Impact factor: 5.063

Review 4.  Side Effects and Efficacy of Neuraxial Opioids in Pregnant Patients at Delivery: A Comprehensive Review.

Authors:  Sarah Armstrong; Roshan Fernando
Journal:  Drug Saf       Date:  2016-05       Impact factor: 5.606

5.  Addition of dexmedetomidine to epidural morphine to improve anesthesia and analgesia for cesarean section.

Authors:  Yichen Yang; Chengjun Song; Chengwei Song; Chengwen Li
Journal:  Exp Ther Med       Date:  2020-01-07       Impact factor: 2.447

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.