Literature DB >> 6703343

Phenoxyethanol as a nontoxic substitute for formaldehyde in long-term preservation of human anatomical specimens for dissection and demonstration purposes.

K W Frølich, L M Andersen, A Knutsen, P R Flood.   

Abstract

Formaldehyde has recently been declared a potential carcinogen. Occupational health authorities throughout the world are therefore likely to put stricter regulations to its use also within anatomical disciplines. We have been able to reduce the atmospheric concentration of formaldehyde in our dissection rooms to below the detection limit of a conventional Dräger tube multigas analyzer (i.e., below 0.5 ppm or 0.6 mg formaldehyde/m3 air), by extracting previously formaldehyde-fixed material for more than 3 months in 1% phenoxyethanol in tap water. In this fluid our material has remained soft and flexible with a consistency and color retention suitable for dissection and demonstration purposes for up to 10 years. Fungal attacks are rare and we have been unable to raise bacteria from such specimens. Even the microscopical structure of most tissues remains satisfactory after 5 years in 1% phenoxyethanol. The unpleasant and irritating smell traditionally felt in dissection rooms is almost absent in our facilities, but some of our students still mention slight odor, headache, drowsiness, and mild eye, nose, and throat irritation during their dissection practice periods.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6703343     DOI: 10.1002/ar.1092080214

Source DB:  PubMed          Journal:  Anat Rec        ISSN: 0003-276X


  5 in total

1.  Setting up a microneurosurgical skull base lab: technical and operational considerations.

Authors:  Asem Salma; Andrew Chow; Mario Ammirati
Journal:  Neurosurg Rev       Date:  2011-05-26       Impact factor: 3.042

2.  Plastinated knee specimens: a novel educational tool.

Authors:  Sanjeev Lalwani; Renu Dhingra
Journal:  J Clin Diagn Res       Date:  2013-01-01

Review 3.  Human body preservation - old and new techniques.

Authors:  Erich Brenner
Journal:  J Anat       Date:  2014-01-18       Impact factor: 2.610

4.  An improved composition for embalming fluid to preserve cadavers for anatomy teaching in the United Kingdom.

Authors:  E O'Sullivan; B S Mitchell
Journal:  J Anat       Date:  1993-04       Impact factor: 2.610

5.  Phenoxyethanol-Based Embalming for Anatomy Teaching: An 18 Years' Experience with Crosado Embalming at the University of Otago in New Zealand.

Authors:  Brynley Crosado; Sabine Löffler; Benjamin Ondruschka; Ming Zhang; Johann Zwirner; Niels Hammer
Journal:  Anat Sci Educ       Date:  2020-01-21       Impact factor: 5.958

  5 in total