Literature DB >> 6695974

The scalp stimulation test: a clinical alternative to fetal scalp blood sampling.

S L Clark, M L Gimovsky, F C Miller.   

Abstract

Intrapartum fetal heart rate response to various scalp stimuli and its correlation with scalp pH was studied in a prospective manner. One hundred fetuses with heart rate tracings judged by the resident responsible for the patient to be suggestive of fetal asphyxia were entered into the study. Each fetus was subjected to firm digital pressure on the head followed by a gentle pinch of the scalp with an atraumatic clamp. Scalp blood sampling was then performed in the usual manner. Response to either of these stimuli by an acceleration of the fetal heart rate of 15 bpm lasting at least 15 seconds was uniformly associated with a scalp blood pH of greater than or equal to 7.19. Fifty-one fetuses so stimulated responded with an acceleration. Of the remaining fetuses, 19 had a scalp pH less than 7.19 and 30 were associated with a pH greater than 7.19. Clinical application of such a scalp stimulation test could, therefore, reduce the necessity for scalp blood sampling by approximately 50% in the presence of a fetal heart rate pattern suggesting acidosis. Such a provocative test may also be very useful with an abnormal fetal heart rate pattern suggestive of acidosis when the cervix is sufficiently dilated to permit scalp blood sampling.

Entities:  

Mesh:

Year:  1984        PMID: 6695974     DOI: 10.1016/s0002-9378(84)80067-8

Source DB:  PubMed          Journal:  Am J Obstet Gynecol        ISSN: 0002-9378            Impact factor:   8.661


  6 in total

Review 1.  Fetal monitoring and neonatal resuscitation: what the anaesthetist should know.

Authors:  J Guay
Journal:  Can J Anaesth       Date:  1991-05       Impact factor: 5.063

2. 

Authors:  F Béguin
Journal:  Arch Gynecol Obstet       Date:  1995-12       Impact factor: 2.344

Review 3.  Cesarean section, 1988--to have or have not!

Authors:  E J Quilligan
Journal:  West J Med       Date:  1988-12

Review 4.  Intrapartum Electronic Foetal Monitoring : Does it Lead or Mislead?

Authors:  Shakti Vardhan; T K Bhattacharyya; S K Kathpalia; Sps Kochar
Journal:  Med J Armed Forces India       Date:  2011-07-21

5.  Fetal heart rate pattern notification guidelines and suggested management algorithm for intrapartum electronic fetal heart rate monitoring.

Authors:  Thomas Downs; Evelyn Zlomke
Journal:  Perm J       Date:  2007

6.  Effectiveness of fetal scalp stimulation test in assessing fetal wellbeing during labor, a retrospective cohort study.

Authors:  Farzaneh Shakouri; Linda Iorizzo; Hellen Mc Kinnon Edwards; Christina Anne Vinter; Karl Kristensen; Per-Erik Isberg; Nana Wiberg
Journal:  BMC Pregnancy Childbirth       Date:  2020-06-05       Impact factor: 3.007

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.